Cnc faceplate, Home view – Rockwell Automation IASIMP Computer Numerical Control (CNC) Machining Accelerator Toolkit Quick Start User Manual
Page 221

Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012
221
System Application Guide
Chapter 7
CNC Faceplate
The FANUC CNC faceplate is typically launched from the Machine Startup or Equipment Status faceplate’s
corresponding Goto display buttons.
Home View
Table 9 - Faceplate Toolbar Buttons
Function
Button
Icons
Description
Function
Button
Icons
Description
Alarm
The Alarm button indicates a drive fault
condition and activates fault diagnostic
views. A gray bell indicates normal status,
with no faults. A yellow flashing bell
indicates a fault condition.
CNC Control
From the CNC Control display you can
home, start/stop cycle, disable, reset a
CNC fault/alarm, unload the machine,
change tools, gage parts, and more.
Configuration
The Configuration button lets you edit the
faceplate name or name of the device.
Help
The Help button provides information for
the existing view.
CNC Status
From the CNC Status display you can view
general CNC status.
Close
Click the Close button to close the
faceplate.
Faceplate
Toolbar
CNC
Information
Close
Button
Title Bar