67
FANUC CNC Configuration
Chapter 3
6.
Press either the + softkey or the right arrow
function key to advance to the chapter
selection for EtherNet/IP scanner settings,
EIP S SET.
7.
Press the (OPRT) softkey to display available
operations for the EtherNet/IP scanner
settings.
8.
Press either the + softkey or the right arrow
function key to advance to the operation
selection for restore.
9.
Press the RESTORE softkey to display
available operations for the EtherNet/IP
scanner restore operations.
10.
Press the EXECUTE softkey to copy the
parameters from the external USB device to the
CNC parameter memory.
11.
Power down the CNC to accept the changes to
the EtherNet/IP settings.
12.
for the Ethernet adaptor settings (at
select EIP A SET).
The Ethernet board is now configured for the
connection to the supervisory PLC that uses