4 wiring the field current regulator board, 5 replacing the drive fuses, 6 replacing the carrier and drive cover – Rockwell Automation FlexPak 3000 Drive Field Current Regulator Kit, 911FK0041, 911FK0101, 911FK015 User Manual

Page 15: 7 modifying the drive configuration

Advertising
background image

Installing the Field Current Regulator Kit on 1.5 - 30 HP @ 230 VAC and 3 - 60 HP @ 460 VAC Drives

2-3

2.4

Wiring the Field Current Regulator Board

Step 1. The Operator Interface Module (OIM) or Drive Configuration Module (DCM)

must be removed to provide access to the Regulator board. Remove the
screws that hold the OIM or DCM to the carrier, and remove the OIM/DCM.

Step 2. Remove the three screws that hold the Regulator board in place, and slide

the Regulator board slightly to the right.

Step 3. From the back of the carrier, push the end of the Field Current Regulator

cable assembly with the REG P25 connector through the opening in the
carrier (above the ribbon cable). See figure 2.2.

Step 4. Connect the REG P25 connector to the J25 terminal on the Regulator board.

See figure 2.3.

Step 5. Slide the Regulator board back into place and secure it with its mounting

screws.

Step 6. Reinstall the OIM/DCM.

Step 7. Use the supplied cable ties to fasten the Field Current Regulator cable

assembly to the drive’s fan or support bar.

2.5

Replacing the Drive Fuses

Step 1. Remove the three fuses labeled 6FU, 7FU, and 8FU from the drive’s fuse

block.

Step 2. Install the three provided 25 A, 600 V fuses (P/N 64676-30M) in the fuse

block in positions 6FU, 7FU, and 8FU.

Step 3. Locate the replacement fuse table on the back of the carrier. Attach one of

the adhesive fuse rating labels (P/N 179540) over each of the places
indicated in figure 2.4.

2.6

Replacing the Carrier and Drive Cover

Step 1. Close the carrier and secure it in place with its captive screw.

Step 2. Reinstall the drive cover and secure it in place with its screws.

Step 3. Reconnect power to the drive. Hardware installation is complete.

Step 4. Remove the lockout and tag.

Step 5. Turn on power to the drive.

2.7

Modifying the Drive Configuration

Go to chapter 5 for information on setting parameters for the Field Current Regulator
kit.

Advertising