Step 5. Working from the inside of the bottom of the drive, align the Field Current
Regulator board’s mounting holes with the mounting holes on the drive’s right
side panel. See figure 4.2.
Step 6. Working from the outside of the drive, insert one of the mounting screws
(removed in step 1) through one of the mounting holes on the drive’s right
side panel and into the corresponding mounting hole on the Field Current
Regulator board. Tighten the screw to hold the board in place.
Step 7. Repeat step 6 for the remaining three mounting screws.
4.4
Wiring the Field Current Regulator Board
Step 1. The Operator Interface Module (OIM) or Drive Configuration Module (DCM)
must be removed to provide access to the Regulator board. Remove the
screws that hold the OIM (or DCM) to the carrier, and remove the OIM/DCM.
Step 2. Remove the three screws that hold the Regulator board in place, then slide
the Regulator board slightly to the right.
Step 3. From the back of the OIM carrier, push the end of the Field Current Regulator
cable assembly with the REG P25 connector through the opening in the
carrier (above the ribbon cable).
Step 4. Connect the REG P25 connector to the J25 terminal on the Regulator board.
See figure 2.3.
Step 5. Slide the Regulator board back into place and secure it with its mounting
screws.
Step 6. Reinstall the OIM/DCM.
4.5
Reinstalling the OIM Carrier and Cover
Step 1. Swing the mounting panel back into the closed position, and secure it by
twisting the notches on the two plastic anchors into a horizontal position.
Step 2. Close the OIM carrier and secure it in place with its captive screw.
Step 3. Reinstall the OIM/DCM cover.
4.6
Replacing the Drive Fuses
Step 1. Locate the fuse block on the drive’s line fuse panel. See figure 4.2.
Step 2. Remove the three fuses labeled 6FU, 7FU, and 8FU from the fuse block.
Step 3. Install the three provided 25 A, 600 V fuses (P/N 65676-30M) in the fuse
block in positions 6FU, 7FU, and 8FU.
4.7
Reinstalling the Drive Cover
Step 1. Reinstall the cover over the right side of the drive.
Step 2. Reinstall the plastic cover over the drive’s line fuse panel. Hardware
installation is complete.
Step 3. Reconnect power to the drive.
Step 4. Remove the lockout and tag.
Step 5. Turn on power to the drive.