Modifying the Drive Configuration

5-1

C

HAPTER

5

Modifying the Drive Configuration

Before you can use the Field Current Regulator kit, you must set the parameters listed
below in the FlexPak 3000 drive. These parameters are described in sections 5.1 and
5.2.

Parameter 510 (

MOTOR

HOT

FLD

AMPS

)

Parameter 511 (

FIELD

ECONOMY

REF

)

In addition, the input parameters listed below may need to be adjusted in order to tune
the field control loop. Refer to your drive’s instruction manual for a complete
description of these parameters.

Parameter 501 (

FIELD

ECONOMY

DELAY

)

Parameter 512 (

FIELD

LOSS

THRESHOLD

)

Parameter 513 (

FIELD

REF

REGISTER

)

Parameter 514 (

FIELD

PI

PROP

GAIN

)

Parameter 515 (

FIELD

PI

LEAD

FREQ

)

Parameter 516 (

FLD

FEEDBACK

GAIN

ADJ

)

Parameter 517 (

FIELD

AUTO

WEAKEN

)

Parameter 518 (

FLD

WEAKEN

THRESHOLD

)

Parameter 519 (

FLD

WEAKEN

PROP

GAIN

)

Parameter 520 (

FLD

WEAKEN

LEAD

FREQ

)

Parameter 587 (

FIELD

DELTA

HIGH

LIM

)

Once the Field Current Regulator kit is installed and the drive is configured, the
following output parameters can be used. Refer to your drive instruction manual for
complete descriptions of these output parameters.

Parameter 586 (

FLD

CURRENT

REGULATOR

)

Parameter 588 (

FIELD

DELTA

)

Parameter 589 (

FIELD

FEEDBACK

)

Parameter 590 (

FIELD

REFERENCE

)

If you are installing and setting up the Field Current Regulator kit as part of your initial
drive setup, and are using the quick start procedure described in the drive’s instruction
manual, you will be prompted for parameter 510 (

MOTOR

HOT

FLD

AMPS

). In this case,

after you finish with the quick start procedure, make sure that you set parameter 511
(

FIELD

ECONOMY

REF

).