Baumfolder Flexifold: Pile Folder (in 2004) User Manual

Page 21

Advertising
background image

TP10496

PAGE 21

2.0 INTRODUCTION

The Flexifold Pile Feeder is a modular

addition to the Flexifold Folding System. This

feeder has these features that adds value to the

folding system.

- Higher load capacity - 18 inch (45.8cm)

stack

- Register - aligns the paper prior to

folding for improved folding accuracy.

- Gap size - allows for larger gaps between

sheets, allowing for better folding on

some fold configurations

- Sheet counter

- Batch counter

- Speed slaved to the first folding station

- Single sheet operating mode for ease of

set up

- Ability to vary sheet gap

- Pile table reload position at a constant

height

- Jam or not running inhibit from first fold

station (parallel)

3.0 SPECIFICATIONS

Model Name

Flexifold Pile Feeder

Minimum Sheet Size

4x6” (10.2 x 15.2cm)

Maximum Sheet Size 14 x 20” (35.5 x 50.8cm)

Maximum Paper Weight

65 lb Cover

Maximum Stack Height

18” (45.7cm)

Overall Dimensions

Height

42.5” (108cm)

Width

33.1” (84.0cm)

Length

51.2” (130.0cm)

Operating Voltage

230VAC/1PH/50Hz

115VAC/1PH/60Hz

Supplied Power

230VAC/1PH/50Hz/25AMPS

115VAC/1PH/60Hz/25AMPS

Mating Connector

230VAC

- CEE7

115VAC - NEMA5-30R

4.0 PILE FEEDER & REGISTER

INSTALLATION INSTRUCTIONS

1. If applicable, remove existing short

pile feeder from parallel folding unit. Be sure to

disconnect both hoses.

2. Register will drop directly into parallel

folding unit by aligning the four locating slots in

the register side frames with four locating pins in

the parallel unit.

3. Install register drive guard onto register

drive gear block after register has been installed on

parallel folding unit.

4. Roll pile feeder unit to register. There is

one locating block w/pin on each side of feeder.

There is also one locating slot in each register

side frame for locating pins in blocks on feeder.

Register side frames should fit in between locating

blocks on feeder. Pile feeder has four height

adjustable casters, adjust these up and/or down

until locating pins on pile feeder slide into slots on

register side frames. Now lock feeder into place by

rotating locking pawls on register frames over pins

in locating blocks on pile feeder.

Advertising