A. Pile Height Sensor Sensitvity

Adjustment - This adjustment is made by turning

the pot located on top of the sensor next to the

indicator. This will increase or decrease the

sensitivity of the sensor.

Note: Do not turn the pot adjustment past it stops.

Damage to the sensor may result.

B. Pile Height Vertical Location

Adjustment - This adjust can be made by loosening

the locking lever holding the sensor in place. The

sensor will now be free to move vertically in its

retainer. Tighten the locking lever to lock the

sensor in place. Only tighten the locking lever so

much that it holds the sensor in place. Do not over

tighten the locking lever, as this could damage the

sensor.

This height is adjusted at the factory so that

it is 1/2” (38.10mm) above the paper stack.

C. Pile Height Sensor Plastic Ring- This

plastic donut prevents the sensor from detecting

objects such as side guides. It may be necessary to

lower or raise this ring by looseing the set screw

holding it in place, depending on the location of

the side guides.

Sensitivity

Adjustment

Plastic Ring

Locking Lever

Indicator