18.0.2 PILE FEEDER SENSOR TESTS

This test will test the operability of each sensor contained in the following table. As each sensor

is operated, its status should switch between “INACTIVE” and “ACTIVE”. If the display does not

switch from inactive to active when the sensor is operated, something is wrong with the sensor, display

assembly, communication cable or controller board. Exiting this Diagnostic program can be done at any

time by scrolling to the EXIT screen and pressing the Enter Key, 7.

1. Turn the main Pile Feeder Power Switch on.

2. Press the Pile Feeder Start Key, 2.

3. Press the Diagnostic Key, 5. The message

will be displayed.

4. Press the Enter Key, 7, to enter the diagnostic tests or press the Reset Key, 5, to exit. The

message

5. Press the Up Arrow Key, 14, until the message

is displayed.

6. Press the Enter Key, 7, and the message

will be displayed.

7. Using the Up/Down Arrow Keys, 14/13, select the sensor test of interest. In the table on the

next page, there is a list of each sensor test available in this diagnostic program, along with the normal

and operated state displays, and the proper way to check functionality of each sensor.

8. To exit the sensor tests, use the Up Arrow Key, 14, until the message

is displayed.