Baumfolder Flexifold: Pile Folder (in 2004) User Manual

Page 40

Advertising
background image

TP10496

PAGE 40

The Batch Output Indicator, 17, should be flashing on and off. Also, The text in the display

on the Operator Panel should be switching from “OFF” and “on” in relation with the Batch Output

Indicator. This also appiles to each indicator listed in the Indicator Test Table.

7. Using the Up/Down Arrow Keys, 14/13, select the output test of interest. In the table on the

next page, there is a list of each output test available in this diagnostic program, along with remarks on

how the chosen output should function normally.

8. To exit the sensor tests, use the Up Arrow Key, 14, until the message

is displayed.

9. Press the Enter Key, 7, and the operator panel will return to the

screen.

10. Use the Up Arrow Key, 14, until the message

is displayed.

11. Press Enter Key, 7, and the operator panel display will return to the main count screen.

NOTE: The Input Indicator is not listed in the Indicator Test Table or part of the Diagnostic Program.

To test the Input Indicator on the Operator Panel, run and object under the sheet count sensor. The Input

Indicator on the Operator Panel should turn on and off. This test will also check for proper operation of

the sheet count sensor and ensure the signal is getting to the control board properly.