background image

Output OFF

Taught Position

(e.g., wall or floor)

Position
-100 mm

Position

+100 mm

Sensor
Output

ON

Sensor
Output

OFF

Any object in this area will switch the output,
whether or not the object returns a good signal to the sensor.

Sensing Range

200 mm

Output ON

Figure 6. An application for Auto-Window feature (retroreflective mode)

Push Button Method

1. Enter Programming Mode

Action

Result

Push and hold the Output 1 button for output 1 or the Output 2
button for output 2

The corresponding output LED turns ON Red and the sensor waits
for first limit.

2. Teaching the Limit

Action

Result

Position the sensor for the midpoint of the sensing window

Click the same button (Output 1 button for output 1; Output 2
button for output 2)

The LED for the selected output flashes red

3. Re-teaching the Limit

Action

Result

Without moving the target, click the button again (Output 1
button for output 1; Output 2 button for output 2)

LED for the selected output turns solid amber and the sensor
stores the sensing window for the selected output. The sensor
returns to RUN mode.

Remote Line Method (0.04 s < T < 0.8 s)

1. Enter Programming Mode

Action

Result

No action required

The corresponding output LED turns solid Red and the sensor waits
for first limit.

2. Teaching the Limit

Action

Result

Position the target for the midpoint of the sensing window

For Output 1: single-pulse the remote line

T

For Output 2: double-pulse the remote line

T

T

T

The LED for the selected output flashes red

U-GAGE QT50UDB Series Sensors with Dual-Discrete Outputs

P/N 110112 Rev. B

www.bannerengineering.com - tel: 763-544-3164

7