System installation – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 19

Advertising
background image

P/N 68413 rev. A

17

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN Point

Instruction Manual

System Installation

Sensing Mode Configurations

In opposed-mode configuration, the emitter and receiver are 

mounted opposite from each other to form a single beam (see

Figure 3-3). Opposed-mode configuration can be combined with 

vertical corner mirrors for perimeter-guarding applications, as 

shown in Figure 3-4 and described in Section 3.3.6.

Access-Guard Configurations

In access-guard configuration, the emitter and receiver are 

used with two angled mirrors to create multiple beams from one 

EZ-SCREEN Point System – in effect, forming a vertical light 

grid using one beam. The ACCESS-GUARD kit is available for 

constructing this configuration (see Figure 3-3 and Section 2.1).

Figure 3-3. EZ-SCREEN Point sensing mode configurations

Two-Beam Opposed-Mode
configuration

Emitter

Receiver

Receiver

Emitter

Receiver

Emitter

ACCESS-GUARD configuration set too far apart and misaligned can result in

voids in the sensing area. Path A is unintended.

ACCESS-GUARD configuration

Receiver

Emitter

Intended Path

Path A

Emitter

Emitter

Receiver

Emitter

Receiver

Mirror #2

Mirror #1

Single opposed mirror leaves

dangerous voids in the sensing area

Both emitters facing the same

direction provides crosstalk potential

Unacceptable Configurations

Receiver

Advertising
This manual is related to the following products: