Troubleshooting and maintenance, 2 emitter error codes – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 47

Advertising
background image

P/N 68413 rev. A

45

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN Point

Instruction Manual

Troubleshooting and Maintenance

5.1.2 Emitter Error Codes

NOTE: The emitter flashes the number 2 followed by the other error code digit, pauses, then flashes the sequence again.

Diagnostic

Display

Error Description

Appropriate Action

Test Input Error
This error can occur if excessive 
noise is present on the test input .

•  Reset the emitter by disconnecting and reapplying power to the emitter (see 

Section 4.2).

•  If the error clears, perform a Daily Checkout procedure (Section 6.4) and if OK, 

resume operation . If the system fails the Daily Checkout procedure, replace the 
emitter .

If the error continues, check the ground connection (terminal 1). 
•  If the sensor has a good earth ground connection to terminal 1, check for 

noise on the test input wiring (see Sections 5.2 and 5.3).

Emitter Error
This error can occur either due to
excessive electrical noise or due to 
an internal failure .

•  Reset the emitter by disconnecting and reapplying power to the emitter (see 

Section 4.2).

•  If the error clears, perform a Daily Checkout procedure (Section 6.4) and if OK, 

resume operation . If the system fails the Daily Checkout procedure, replace the 
emitter .

If the error continues, check the ground connection (terminal 1).
•  If the sensor has a good earth ground connection to terminal 1, check for 

electrical noise (see Section 5.2).

• If the error continues, replace the emitter .

Excessive Noise Error
This error can occur due to
excessive electrical noise.

•  Reset the emitter by disconnecting and reapplying power to the emitter (see 

Section 4.2).

•  If the error clears, perform a Daily Checkout procedure (Section 6.4) and if OK, 

resume operation . If the system fails the Daily Checkout procedure, replace the 
emitter .

•  If the error continues, check the ground connection (terminal 1).
•  If the sensor has a good earth ground connection to terminal 1, check for 

electrical noise (see Section 5.2).

If the error continues, replace the emitter .

Figure 5-2. Emitter error codes

Advertising
This manual is related to the following products: