System installation, Warning, Caution. . . shock hazard – Banner EZ-SCREEN­ Safety Light Curtain Systems User Manual

Page 39

Advertising
background image

P/N 68413 rev. A

37

Banner Engineering Corp.

Minneapolis, U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

EZ-SCREEN Point

Instruction Manual

System Installation

+24V dc

0V dc

Reset

PE 1

dc Com 2

+24V dc 3

(Not Used) 4

RESET 5

EDM1 6

EDM2 7

OSSD1 8

OSSD2 9

S1

S2
Y1

Y2

Y3

Y4

14

24

34

13
23
33

S4

S3

EZ-SCREEN

Receiver

(1)

IM-T-9A

+

+

K2

K1

MPCE

2

Feedback (optional)

MPCE

1

Machine

Control

(2)

* Installation of transient suppressors across

the coils of MPCE1 and MPCE2 is
recommended (see Warning).

+

+

*

*

1) See Section 3.5 for more information

on Reset input and hookup.

2) See Section 3.7.3 for information on

EDM input and hookup.

3) TEST input must be jumpered if not

used. Typically a Normally Open switch
held closed. See Section x.x for
information on TEST input and hookup.

Figure 3-21. EZ-SCREEN receiver generic hookup – interface module

(1-channel EDM, key reset)

WARNING . . .

Use of Transient
Suppressors

If transient suppressors are used, they 
MUST be installed across the coils of 
the machine control elements. NEVER 
install suppressors directly across the
contacts of the IM-T-..A Module! It is 
possible for suppressors to fail as a
short circuit . If installed directly across
the contacts of the IM-T-..A Module, a 
short-circuited suppressor will create an 
unsafe condition .

WARNING . . .

OSSD Interfacing

To ensure proper operation, the EZ-SCREEN OSSD output parameters and machine input parameters must be considered when 
interfacing the EZ-SCREEN solid-state OSSD outputs to machine inputs.

Machine Control circuitry must be designed so that the maximum load resistance value is not exceeded and that the  maximum specified OSSD 
OFF-state voltage does not result in an ON condition.
Failure to properly interface the OSSD outputs to the guarded machine could result in serious bodily injury or death.

WARNING . . .

Proper Wiring

The generalized wiring 

configurations shown are provided only 
to illustrate the importance of proper
installation .
The proper wiring of the EZ-SCREEN
System to any particular machine is
solely the responsibility of the
installer and end user.

CAUTION. . .

Shock Hazard

Always disconnect all

power from the EZ-SCREEN System
and the guarded machine before
making any connections or replacing
any component.
 Use extreme caution 
to avoid electrical shock at all times. 
Serious bodily injury or death could
result.

Advertising