3.3.5 Adjacent Reflective Surfaces

A reflective surface located adjacent to the light beam(s) may 

deflect light around an object in the beam(s). In the worst case, 

such a situation may allow an object to pass undetected through 

the beam(s).
This reflective surface may result from shiny surfaces or glossy 

paint on the machine, the workpiece, the floor or the walls. 
Beams deflected by reflective surfaces are discovered by 

performing the trip test portion of the final alignment procedure

and the periodic checkout procedures (Sections 3.6 and 6). To

eliminate problem reflections:
•  If possible, relocate the sensors to move the beam away 

from the reflective surface(s), being careful to maintain 

adequate separation distance .

•   Otherwise, if possible, paint, mask or roughen the shiny

surface to reduce its reflectivity.

•   Where these are not possible (as with a shiny workpiece), 

include a means of restricting the receiver’s field of view or 

the emitter’s spread of light in the sensor mounting .

•  Repeat the trip test to verify that these changes have 

eliminated the problem reflection(s). If the workpiece is 

especially reflective and comes close to the light beam(s), 

perform the trip test with the workpiece in place.

WARNING . . .

Avoid Installation Near

Reflective Surfaces

Avoid mounting the EZ-SCREEN Point near

any reflective surfaces. A reflective surface located nearby
may reflect light around an object or person, preventing its
detection by the receiver. This possibility is detected during
the trip test.
Failure to prevent reflection problems will result in incomplete
guarding; serious bodily injury or death could result.

Emitter

Receiver

Operating
Range (R)

d

d

Do not position

reflective surfaces

within the shaded area

Short-Range Models

Operating Range 0.8 to 3 meters (2.6' to 10'): d = 131 mm (5.2')
Operating Range 3 to 20 meters (10' to 65'): d = 0.0437 x R (meters or feet)

Long-Range Models

Operating Range 15 to 70 meters (49' to 230'): d = 0.0437 x R (meters or feet)

Figure 3-9. Adjacent reflective surfaces

CAUTION . . .

Proper Model Selection

Ensure proper selection of emitter models, with 
respect to range (operating distance) between emitter 

and receiver, to minimize the possibility of optical short circuits (see 
Sections 2.1 and 3.3.4).