Ql50 luminescence sensor, Remote programming and push-button lockout, Quick-set programming – Banner QL50 Series User Manual

Page 3

Advertising
background image

P/N 112151 rev. C

3

QL50 Luminescence Sensor

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Output OFF

Output ON

Background

Condition

Target

Object

Condition

Least
Luminescent

Most

Luminescent

Figure 2. Quick-Set programming

Remote Programming and Push-Button Lockout

The remote line allows programming with a remote switch. It can also be used to lock

out the push button, preventing unwanted tampering with the push button. Connect

the white remote wire to 0V if not used.
• To disable the push button and the remote program wire, connect the white remote

wire to high supply potential (+V dc), then power the sensor ON.

• To program the sensor using the remote line, connect a normally open (N.O.) switch

between the white remote wire and high supply potential (+V dc), then power the

sensor ON. This enables remote programming.

• To enable the push button, turn the sensor power OFF, remove the white wire from

high supply, and then turn sensor power ON.

Quick-Set Programming

Quick-Set programming teaches the QL50 Sensor to respond to a specific

luminescence intensity and ignore less-intense luminescence conditions. The

programmed setting will be light operate; the sensor will respond to an equivalent or

more luminescent condition.
Sensing the luminescent target will close the normally-open output, turn the yellow

Output LED ON, and cause the output to conduct current (see Figure 2).

*The Yellow LED may be ON or OFF, depending on target and range.

**The Green LED may go OFF if a target is presented at the sensor threshold.

Procedure

Result

Push Button

Remote Line

Position

Target

• Position luminescent target

for sensing.

• Position luminescent target for

sensing.

Yellow Output LED: ON (or OFF*)

Green Power LED: ON (or OFF**)

Program

Sensor

• Press and hold push

button (approx. 2 sec.)

until green Power

LED turns OFF, then release.

• Hold remote line (white wire)

high (approx. 2 sec.) until

green Power LED turns OFF,

then release.

Yellow Output LED: OFF, then ON

Green Power LED: OFF, then ON

Sensor returns to RUN mode

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

10 seconds

10 seconds

4 seconds

4 seconds

2 seconds

2 seconds

T

SET

SET

SET

SET

SET

SET

SET