Ql50 luminescence sensor, Sensor setup output off-delay option – Banner QL50 Series User Manual

Page 5

Advertising
background image

P/N 112151 rev. C

5

QL50 Luminescence Sensor

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Procedure

Result

Push Button

Remote Line

Access

SETUP

Mode

• Press and hold push

button (approx. 10 sec.)

until Power LED

turns OFF, then flashes

green, then stays OFF.*

• Hold remote line (white

wire) high (approx. 10 sec.)

until Power LED turns OFF,

then flashes green, then stays

OFF. Open remote line.*

Yellow Output LED: OFF (no target)

Green Power LED:

ON 1 second, then

OFF 1 second, then

Flashing 8 seconds, then

OFF

Delay

Status

• Watch for Power

LED to flash green to

indicate Delay status.

• Watch for Power LED to flash

green to indicate Delay status.

Yellow Output LED: OFF

Green Power LED:

Flashes 2x - no delay

Flashes 4x - delay active (20 ms)

Change

Delay

Setting

• To change delay, quickly

press (“click”)

push button and watch

for Power LED to flash green.

• Repeat step to activate or

deactivate delay, as desired.

• To change delay, pulse remote

line again, and watch for

Power LED to flash green.

• Repeat step to activate or

deactivate delay, as desired.

Yellow Output LED: OFF

Green Power LED:

Flashes 2x - no delay

Flashes 4x - delay active (20 ms)

Exit

SETUP

Mode

• Wait 10 seconds.*

• Wait 10 seconds.*

Yellow Output LED: OFF

Green Power LED: ON

Sensor returns to RUN mode with new setting.

* Sensor has a 10-second time-out. If a 10-second interval elapses without the button being pushed (or the remote line being pulsed), the

sensor returns to RUN mode with the current delay setting stored.

Sensor

Output

OFF-Delay (20 ms)

Output Ends

Output

Starts

Figure 4. OFF-delay: output continues for

20 ms after sensing stops

Sensor Setup

Output OFF-Delay Option

This setup procedure toggles the delay status between active and inactive status.
Setting an output OFF-delay extends the duration of the sensor’s ON output by 20 ms.

See Figure 4.
The sensor will retain the most recent delay setting if a loss of power occurs.
NOTE: The QL50 Sensor is factory-set to power up without an output OFF-delay.

SET

SET

SET

SET

SET

SET

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

10 seconds

10 seconds

4 seconds

4 seconds

2 seconds

2 seconds

T

SET

SET

SET

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

10 seconds

10 seconds

4 seconds

4 seconds

2 seconds

2 seconds

T

SET

SET

SET

SET

Advertising