Ql50 luminescence sensor, Specifications – Banner QL50 Series User Manual

Page 7

Advertising
background image

P/N 112151 rev. C

7

QL50 Luminescence Sensor

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Sensing Beam

Ultraviolet LED (370 nm)

Supply Voltage

10 to 30V dc, 2Vpp max ripple

30 mA max exclusive of load

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

PNP or NPN discrete output, depending on model

30V dc max

Leakage Current: <1 µA

Output Rating

100 mA maximum load

Output Protection

Protected against output overload and short circuit

Output Response Time

250 microseconds

Adjustments

1 push button (set), and remote program wire:

• Fine-detect autoset for Light Operate or Dark Operate

• 20 ms output OFF-delay

• Remote wire to +V dc for remote programming and/or push-button lockout

Indicators

Yellow Output LED: ON when output is conducting

Bicolor Ready/Error LED: Green ON = Default and Quick-Set programming RUN mode

Green OFF = Threshold

Green Flashing = Fine-Detection Program mode/Delay status

Green/Red bicolor flashing = programming error

Construction

ABS shock-resistant housing; glass lens and window (tilted, antireflective)

Environmental Rating

IEC IP62

Connections

4-pin Euro-style (M12) swivel QD connector. Cable required; see page 8 for available cable options.

Operating Conditions

Temperature: -25° to +55°C (-13° to +131°F)

Max. Relative Humidity: 90% at 50°C non-condensing

Data Retention

EEPROM nonvolatile memory

Sensing Range

0 to 40 mm (0 to 1.57")

Maximum signal at 10 mm (0.39")

Spot Diameter

1.5 mm @ 10 mm (0.059" @ 0.39")

Ambient Light Rejection

According to EN 60947-5-2

Shock Resistance

30 G; 3 shocks per axis; 11 ms duration

Vibration

0.5 mm (0.02") amplitude; 10 to 60 Hz frequency; 30 minutes for each X, Y, Z axis

Certifications

Specifications

LISTED

US

Advertising