Maintenance, Replacement parts – Banner Mechanical E-Stop Buttons User Manual

Page 3

Advertising
background image

Maintenance

At machine set up, a Designated Person

1

should test each emergency stop push button for proper machine shutdown

response.

The Designated Person should check the emergency stop buttons for proper operation, physical damage, button looseness,

and excessive environmental contamination. This should take place on a periodic schedule determined by the user, based

on the severity of the operating environment and the frequency of switch actuations

Adjust, repair, or replace components as needed. If inspection reveals contamination on the switch, thoroughly clean the

switch and eliminate the cause of the contamination. Replace the switch and/or appropriate components when any parts or

assemblies are damaged, broken, deformed, or badly worn; or if the electrical/mechanical specifications (for the

environment and operating conditions) have been exceeded.

Always test the control system for proper functioning under machine control conditions after performing maintenance,

replacing the emergency stop device, or replacing any component of the device.

Replacement Parts

8-LP2T-B6644

22.5 mm plastic button (mounting

adapter sold separately)

Twist to release, mechanical latching

ISO 13850 (EN 418) compliant

Diameter 40 mm (without mounting

adapter)

8-LM2T-C01

Normally closed (N.C.) positively

driven contact element

Direct (positive) opening operation

per IEC/EN 60947-5-1

8-LM2T-B6644

22.5 mm metal button (mounting

adapter sold separately)

Twist to release, mechanical latching

ISO 13850 (EN 418) compliant

Diameter 40 mm (without mounting

adapter).

8-LM2T-C10

Normally open (N.O.) auxiliary contact

element

8-LM2T-AU120

Metal mounting adapter for metal button

8-LM2T-AU115

60 mm diameter

Non-adhesive plastic legend with

“Emergency Stop” inscription

LPZP1A5

Compact size - 70mm x 70mm x 56mm (2.7” x 2.7” x 2.2”)

One 22mm hole (with key way) for installation of emergency stop palm/push button

Maximum of three contact blocks

Polycarbonate construction

Wire entry via three sides (M16, M20 or M25) or the bottom (M16)

Environmental rating: IP66, IP67 and IP69K (with proper installation and rated button)

Mounting hole location (x4) - 45mm x 58mm

1 A Designated Person is identified in writing by the employer as being appropriately trained to perform a specified checkout procedure. A Qualified Person

possesses a recognized degree or certificate or has extensive knowledge, training, and experience to solve problems relating to the emergency stop

installation (reference ANSI B30.2).

SSA-EB Series Emergency Stop Buttons

P/N 111880 Rev. A

www.bannerengineering.com - tel: 763-544-3164

3

Advertising