5.1.5 DVCFG (Device Configuration) Menu

On Gateways, the DVCFG menu allows users to set various device-specific parameters, including the network ID (NID),

slave ID (SLID), baud rate, and parity. In extended address mode, use this menu to also set the maximum number of

radio devices (MAXN) within the network and the extended address binding code (XADR).

*

DVCFG

Single-click

Button 2

Double-click Button 2

Even

None

Odd

Single-click

Button 2

Single-click

Button 2

SAVES

DISPLAYED

VALUE

Single-click B1

19200

9600

38400

Single-click

Button 2

Single-click

Button 2

SAVES

DISPLAYED

VALUE

NEW XX

Single-click

Button 2

Single-click

Button 2

adjust rotary switches

to set the network ID

SAVES NEW

VALUES

CUR XX

Single-click

Button 2

Single-click

Button 2

adjust rotary switches

to set slave ID, using

button 1 to select the

digits

SAVES NEW

VALUES

(NID)

(SLID)

(BAUD)

(PRTY)

Network ID

Slave ID

Baud Rate

Parity

Single-click B1

NEW XX

Single-click Button 1 to advance through menu

CUR XX

Double-click Button 2

Double-click

Button 2

* Set to 000000 to use the serial number.

Device Config

16

8

32

Single-click

Button 2

Single-click

Button 2

SAVES

DISPLAYED

VALUE

Single-click B1

(MAXN)

Timing

48

MANUAL

AUTO

AUTO

SET

Single-click

Button 2

Single-click

Button 2

Single-click B1

(XADR)

Extended Addressing

XADR

ADJUST ROTARY

SWITCH TO

SET XADR

Single-click

Button 2

XXXXXX

Single-click B1

Single-click

Button 2

CONFRM

XADR

XXXXX

NETWRK

Single-click

Button 2

BINDNG

Single-click

Button 1 or 2

Reboot

SAVED

*

Gateway

Baud and Parity. The options for baud rate are: 19200, 38400, or 9600. For parity, select None, Even, or Odd.

Extended Address (Binding) Code. Binding Nodes to a Gateway ensures the Nodes only exchange data with the

Gateway they are bound to. After a Gateway enters binding mode, the Gateway automatically generates and

transmits a unique extended addressing (XADR), or binding, code to all Nodes within range that are also in binding

mode. The extended addressing (binding) code defines the network, and all radios within a network must use the

same code.

Max Nodes. Selecting the maximum number of system radio devices (Gateway and all Nodes) changes the timing

for the wireless network. For example, if you are running four Nodes in your wireless network, set the system's

maximum device count to 8. This allows up to 8 radio devices, including the Gateway, in the wireless network and

offers the highest throughput, 62.5 milliseconds, for each Node. The choices are 8, 16, 32, and 48 devices.

Network ID. The Network ID (NID) is a unique identifier you assign to each wireless network to minimizes the

chances of two collocated networks interfering with each other. Assigning different NIDs to different networks

improves collocation performance in dense installations.

Slave ID. The slave ID is an identifying number used for devices within a Modbus system. By default, Gateways

are set to Modbus Slave ID 1. When using more than one Modbus slave, assign each slave a unique ID number.

On Nodes, use the DVCFG to set the network ID (NID) and extended address binding code (XADR). The Node address

(NADR), also referred to as a Node ID or device address, is only functional on some models.

SureCross Wireless I/O Networks

35