Installation and alignment, 2 emitter and receiver hookups, 3 diagnostic led indicators – Banner A-GAGE MINI-ARRAY Series User Manual

Page 12: 4 optical alignment

Advertising
background image

12

P/N 117167 rev. A

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

MINI-ARRAY

®

Two-Piece Measuring Light Screen

3.2 Emitter and Receiver Hookups

Connect the emitter and receiver cables as

shown in Figure 3-6.
Receiver Output 1: (OUT1) is an open-

collector NPN transistor switch rated at

30V dc max., 150 mA max. It is protected

against overload and short circuits.
Receiver Alarm: (ALARM) is an open-

collector NPN transistor switch rated at

30V dc max., 150 mA max. It is protected

against overload and short circuits.
Both outputs are current sinking.

3.3 Diagnostic LED Indicators

The emitter has a single Red status LED.

The receiver’s three LEDs (Green, Yellow,

and Red) are used in combination to

diagnose system status.



«Ž

Ь…

Юi

А`

А`

L>Ài



«Ž

Ь…


Юi

³
q

£И‡Од6К`V

*°-°К6К³
*°-°К6Кq

-9 К³
-9 Кq

"1/£

"1/УЙ,

К{nxК³
К{nxÊq

- 

- 

*°-°К6³
*°-°К6q
-9 ʳ
-9 Êq

,iViˆÛiÀ

“ˆÌÌiÀ

œ>`Ê£

œ>`КУ

К*œЬiА

-Х««Ю

МœÊiÝÌiÀ˜>
‡{nx
`iۈViÊÌiÀ“ˆ˜>

˜œ

Vœ˜˜iV̈œ˜

Figure 3-5. A-GAGE MINI-ARRAY Two-Piece Measuring Light Screen hookup diagram

Receiver LED Condition

System Status

Possible Action

Green

Yellow

Red

ON

OFF

OFF

Emitter/receiver pair aligned

• None

ON

ON

OFF

Emitter/receiver pair aligned with dirty lens

• Clean lenses

• Align emitter and receiver

OFF

OFF

ON

Emitter/receiver pair blocked

• None

OFF

ON

ON

Emitter/receiver pair blocked with dirty lens

• Clean lenses

• Align emitter and receiver

ON

ON

ON

Receiver error

• Replace receiver

ON

Flashing

@ 2 Hz

OFF

Degraded mode; emitter/receiver pair aligned

• Clean lenses

• Align emitter and receiver*

OFF

Flashing

@ 2 Hz

ON

Degraded mode; emitter/receiver pair blocked

• Clean lenses

• Align emitter and receiver*

Flashing

@ 2 Hz

OFF

Flashing

@ 2 Hz

Emitter is not functioning

• Connect emitter

Emitter LED Condition

Emitter Status

Possible Action

Red ON

Emitter operating properly

• None

Red Flashing @ 1 Hz

Emitter is degraded

• Replace emitter

Red Flashing @ 5 Hz

Emitter has power, but receiver is not hooked up

• Connect or replace receiver

3.4 Optical Alignment

After connecting the cables per Figure 3-5, apply 16-30V dc power to the sensor.

Rotate the emitter and/or receiver as necessary to align them. When aligned, the

receiver Green LED is ON. Align the emitter and receiver until the receiver’s Green

LED is ON and the Yellow and Red LED are OFF.

Installation and Alignment

* If after cleaning the emitter and receiver lenses, the emitter diagnostic is solid Red, consider replacing the receiver.

Advertising