Appendix a, Appendix a. serial communication, Serial communication data format – Banner A-GAGE MINI-ARRAY Series User Manual

Page 13: Request sensor to scan command (command 0x53)

Advertising
background image

P/N 117167 rev. A

13

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

MINI-ARRAY

®

Two-Piece Measuring Light Screen

Appendix A describes the serial communication data format and commands

that are available to serially communicate over the EIA-485 interface. The

serial commands can be used to initiate scanning, request sensor light channel

information, request system status, and request one or two sensor measurements.

The serial communication data format utilized by the sensor is described and

related to the sensor commands; examples follow.

Serial Communication Data Format

The serial communication utilizes a standard universal asynchronous receiver/

transmitter architecture. The sensor baud rate can be 9600, 19200, or 38400.

The data will have one start bit, one stop bit, no parity, eight data bits and is

transmitted least significant bit first. The serial communication string format will

consist of a start-of-header byte, a sensor-identification byte, a command byte, a

count of the data bytes, the data bytes, and a two-byte check sum.
All serial communication will follow this data format. The start-of-header byte

will always have hexadecimal value 0xF4 (244 decimal). The sensor identification

byte can have hexadecimal values ranging from 0x41 through 0x5A (65 through 90

decimal). The command bytes used for the sensor are listed in Table A-1.
The count of the data bytes defines the number of data bytes that will be

transmitted for the particular command. For instance, if four data bytes are

transmitted, then the value for the number of data bytes will equal four. The actual

data bytes follow the byte representing the number of data bytes. The check sum

is a two-byte value that is calculated by summing the previous bytes in the string.

Once the sum is known, then a ones complement of the sum is calculated and

used as the string check sum value. Examples will be given in the description of

each command.

Request Sensor to Scan Command (Command 0x53)

This command will be used when the sensor is configured for host scanning. This

command is useful for instances where multiple sensors are present and sensor

cross talk is an issue. Assuming the sensor ID is 0x41, the command string would

be as follows:
Transmit string to sensor: 0xF4, 0x41, 0x53, 0x00, 0x77, 0xFE
Receive string from sensor: 0xF4, 0x41, 0x53, 0x01, 0x06, 0x70, 0xFE
This receive string would be interpreted as follows:
0xF4 is the start-of-header byte
0x41 is the sensor-identification byte
0x53 is the command requesting the sensor scan initiation
0x01 is the number of data bytes
0x06 is the valid response stating that the sensor initiated a scan
The last two bytes are the check sum in low-byte, high-byte order and calculated

as follows:

0xF4 + 0x41 + 0x53 + 0x01 + 0x06 = 0x18F.
The ones complement of 0x18F = 0xFE70.
Hence the low-byte, high-byte order would be 0x70, 0xFE.

Appendix A. Serial Communication

Appendix A

Command

Value

(Hexadecimal)

Command

Description

0x53

Request Sensor to

Scan

0x64

Request Sensor

to Transmit Each

Optical Channel

State

(0-clear, 1-blocked)

0x66

Request Sensor to

Transmit System

Status Information

0x67

Request Sensor to

Transmit One or Two

Measurement Values

Table A-1.