Specifications

Supply Voltage

and Power

16 to 30V dc. Maximum power 12 watts.

Supply Protection

Circuitry

Protected against transient voltages and reverse polarity

Discrete Output

Configuration

2 Discrete Outputs: Output 1 and Output 2. Outputs can be configured as either open collector NPN or PNP

transistors. For the vehicle separation application, the outputs are factory configured as NPN outputs.

Discrete Output (either NPN or PNP) ratings: Rated at 30V dc max, 150 mA max load, short circuit protected

OFF-State Leakage Current: <10 µA @ 30V dc

ON-State Saturation Voltage: <1V @ 10 mA, <1.5V @ 150 mA

Serial Data Outputs

EIA-485 interface

Baud rate 9600, 19.2 K, 38.4 K

8 data bits, 1 start bit, 1 stop bit, no parity

Controller

Programming

Via EIA-485 to PC-compatible computer running Windows

®

98, NT, ME, XP, 2000 Operating System

Emitter/Receiver

Range

Sensors < 1220 mm (4') long: 0.9 to 16.5 m (3' to 55')

Sensors 1220 mm (4') long: 0.9 to 13.5 m (3' to 45')
NOTE: Maximum range is specified at the point where 3x excess gain remains.

Minimum Object

Sensitivity

Interlaced Mode: 25.4 mm (1.0")*

Other scanning modes: 38.1 mm (1.5")
*NOTE: Assumes sensing is in middle one-third of scanning range.

Sensor Scan Time

See Section 2.1.
NOTE: Worst-case response time is twice the scan time.

Cable Connections

Emitter and receiver connections: See Figure 3-6. For QD versions, use cable listed in Section 2.2.

Emitter and receiver cables may not exceed 80 m (250') each.

Status Indicators

(see Section 3.3 for

more information)

Emitter

Red LED lights for proper operation

Receiver

Green: sensors aligned (> 3x excess gain)

Yellow: marginal alignment (1x-3x excess gain)

Red: sensors misaligned or beam(s) blocked

Environmental

Rating

NEMA 4, 13 (IEC IP65)

Construction

Aluminum housing with black anodized finish; acrylic lens cover

Operating

Conditions

Temperature: -40° to +70° C (-40° to +158° F)

Max. rel. humidity: 95% (non-condensing)

Application Notes

• The emitter and receiver sync lines (pink and white wires) will be damaged if connected to the power supply.

• The receiver EIA-485 interface (red and green wires) will be damaged if connected to the power supply.

2.3 Specifications