Valu-beam, 915 series, 915 series specifications – Banner VALU-BEAM Series User Manual

Page 6

Advertising
background image

VALU-BEAM –

915 Series

page

6

Banner Engineering Corp. • Minneapolis, U.S.A.
Website: http://www.baneng.com • Tel: 888.373.6767

Certifications

Supply Voltage and Current

SMW915 Series: 12 to 28V ac or dc at 50 mA maximum, exclusive of load
SMA915 Series: 90 to 130V ac (50-60 Hz) at 20 mA maximum, exclusive of load
SMB915 Series: 210 to 250V ac (50-60 Hz) at 20 mA maximum, exclusive of load
Exceptions: SMA91E and ESR emitters, which operate from 10-250V ac (50-60 Hz) or dc (10 mA max.)

Supply Protection Circuitry

Protected against transient voltages

Output Configuration

One internal “form C” (single-pole double-throw) electromechanical relay

Output Rating

Max. switching power (resistive load): 150 W, 600 VA
Max. switching voltage (resistive load): 250V ac or 30 V dc (120V ac max. per UL & CSA)
Max. switching current (resistive load): 5A
Min. voltage and current: 1 amp at 5V dc, 0.1 amp at 24V dc
Peak switching voltage: 750V ac (transient suppression recommended)
Mechanical life of relay: 10,000,000 operations

Output Protection Circuitry

Protected against false pulse on power-up

Output Response Time

20 milliseconds ON and OFF; independent of signal strength
(NOTE: 100 millisecond delay on power-up; relay de-energized during this time)

Adjustments

Sensitivity control on rear of sensor allows precise gain setting (turn clockwise to increase gain)

Indicators

Top-mounted red LED indicator lights whenever the sensor sees “light” condition.
Models SMA91E and SMA91ESR emitters have visible-red “tracer beam” which indicates “power on” and
enables easy “line-of-sight” alignment.

Construction

Reinforced black thermoplastic polyester housing, totally encapsulated, molded acrylic lenses and stainless
steel hardware

Environmental Rating

Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12 and 13; IEC IP66

Connections

Emitters: PVC-jacketed 2 m (6.5') or 9 m (30') cable or 3-pin Mini-style quick-disconnect (QD) fitting
available. See page 8.
All Other Sensors: PVC-jacketed 2 m (6.5') or 9 m (30') cable or 5-pin Mini-style quick-disconnect (QD)
fitting available. See page 8.

Operating Conditions

Temperature:

-40° to +50° C (-40° to +122°F)

Maximum relative humidity: 90% at 50°C (non-condensing)

Application Notes

Install transient suppressor (MOV) across any output contact which switches an inductive load

915 Series Specifications