Banner DUO-TOUCH Run Bar with STB Buttons User Manual

Page 8

Advertising
background image

Output Rating

STBVP6 models (solid-state outputs):

Max. load: 150 mA
On-state max. output voltage (no load): +V(supply) − 1.5 V
Off-state leakage current: < 1 μA

STBVR81 models (electromechanical relays):

Max. switching voltage: 125 V dc/150 V ac
Max. switching current: 1 A @ 24 V dc; 0.4 A @ 125 V ac (resistive loads)
Max. resistive power: 24 W dc/50 VA ac
Mechanical life of relays: 10^9 cycles
Electrical life of relays: 1.5 x 10^5 cycles at 1 amp, 24 V resistive

Output Protection Circuitry

All models protected against false pulse on power-up. Models with solid-state outputs have overload and short-

circuit protection.

Output Response Time

20 milliseconds ON/OFF

Indicators

2 green LED indicators:

Power: ON – power applied
Output/fault: ON – button is activated; OFF – button is deactivated; Flashing – internal fault or blocked button

on power-up detected

Connections

PVC-jacketed 2 m (6.5') cables or QD fitting, depending on model; integral 9 m (30') cables are also available.

Accessory QD cables required for QD models.
STBVP6 models: 4-wire (4-pin Mini-style or Euro-style QD)
STBVR81 models: 5-wire (5-pin Mini-style or Euro-style QD)

Environmental Rating

Meets NEMA standards 1, 3, 4, 4X, 12 and 13; IEC IP66

Construction

Totally encapsulated, non-metallic enclosure. Black polyetherimide upper housing; fiber-reinforced PBT polyester

base. Electronics fully epoxy-encapsulated. Supplied with polypropylene (TP) field cover.

Ambient Light Immunity

Up to 100,000 lux

Applicable Agency Standards

(Used with an AT-FM-10K module or an SC22-3 Safety Controller) Analysis of measures for fault avoidance and

fault control according to SIL3 (IEC 61508 and IEC 62061) and Category 4 (EN ISO 13849-1) passes EMI/RFI test

levels as speCified in IEC61496 and IEC62061..

Operating Conditions

0 to 50 °C (32 to 122 °F)
90% @ 55 ºC max. relative humidity (non-condensing)

Application Notes

The polyetherimide upper housing will become brittle with prolonged exposure to outdoor sunlight. Window glass

effectively filters longer wavelength ultraviolet light and provides excellent protection from sunlight. Avoid contact

with strong alkalis, hydrocarbons and fuels. Clean periodically using mild soap solution and a soft cloth.

Two-Hand Control System Note

When the STBVP6 is used with Banner’s SC22-3 Safety Controller in a two-hand control system, the power supply

to the STBVP6 must be of the same voltage that is used to power the Safety Controller and they must have a

common supply ground.

Certifications

STB Self-Checking Optical Touch Buttons

8

www.bannerengineering.com - tel: 763-544-3164

P/N 64136 Rev. C

Advertising
This manual is related to the following products: