Msa series stands, Mounting sensor or mirror to pole – Banner MSA Series Stands User Manual

Page 3

Advertising
background image

P/N 43687 rev. C

3

MSA Series Stands

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Figure 4. Sensor-to-stand mounting for MINI-SCREEN sensor

Figure 5. Mirror-to-stand mounting for MSM Series mirror

Stand Pole

Bracket

(2 supplied with sensor)

2x M3 Screw

(supplied with sensor)

M4 Screw and "T" Nut

(8 supplied with stand; use as needed)

MICRO-SCREEN

(emitter/receiver)

Figure 3. Sensor-to-stand mounting for MICRO-SCREEN sensor

Mounting Sensor or Mirror to Pole

1) Verify that all poles used for the light screen installation are

exactly parallel to each other before mounting sensors and/

or mirrors.

2) Refer to Figures 3, 4, 5, 6, and 7. Assemble the brackets and

hardware as shown in the appropriate figure.

3) Loosely mount the bracket assemblies (see step 2, above) to

the pole using the M4 screws and “T” nuts supplied with the

stand†.

Note that Figures 3, 4 and 5 show the bracket assembly

pointed “outward” (away from the sensor or mirror). One

or both of the bracket assemblies may be reversed to point

“inward,” if necessary. However, access to the mounting

screws becomes less convenient and mirror rotation is

limited when a bracket assembly is pointed inward.

4) Mount the sensor or mirror to its brackets using the screws

supplied with the sensor or mirror. Temporarily tighten those

screws. (NOTE: MICRO-SCREEN sensors from 40" to 48"

long also include one center bracket, and MICRO-SCREEN

sensors from 52" to 72" long include two center brackets.

M4 and “T” nuts are provided with the stands for these

situations. See the MICRO-SCREEN installation manual for

further details.)

5) Slide the sensor or mirror into position along the length of

the pole and tighten the M4 screws into their “T” nuts to lock

the sensor or mirror into position.

IMPORTANT: Step 5 requires accuracy. If no mirrors are

involved in the sensing path, then any feature of the emitter

can be matched in vertical position with the same feature on

the receiver. However, if one or more mirrors is used, the

center of each mirror must match the vertical position of

the center of the defined area of the sensors. The upper and

lower limits of the defined area are dimensioned in the light

screen instruction manual.

6) Loosen the bracket screws (tightened in Step 4) to allow the

sensor or mirror to rotate for alignment. See the light screen

instruction manual for alignment information.

Figure 6. Adapter bracket-to-stand mounting, shown ready for

mounting of EZ-SCREEN or MACHINE-GUARD sensor or

SSM-Series mirror

Figure 7. Swivel bracket-to-stand mounting for SFP12 or

SFP30 Point