Static TEACH and Manual Adjust. Using Manual Adjust with Static TEACH moves the switching threshold. The lighted LED on the bar
graph will move to exhibit the received signal, relative to the switchpoint.

Bar Graph LED Following TEACH

Relative Signal Difference / Recommendation

6 to 8

Excellent: Very stable operation

4 to 5

Good: Minor sensing variables may affect sensing reliability

2 to 3

Low: Minor sensing variables may affect sensing reliability

1

Unreliable: Consider an alternate sensing scheme

Push Button
0.04 seconds < "Click" < 0.8 sec-
onds

Remote Line
0.04 seconds < T < 0.8 seconds

Result

Access TEACH

Mode

• Press and hold Static button > 2

seconds

• No action required; sensor is ready

for 1st TEACH condition

Power LED: OFF
Output LED: ON
Status LEDs: LO & DO alternately flashing
Bar graph: OFF

TEACH Output

ON Condition

• Present Output ON condition
• Click Static button

• Present Output ON condition.
• Single-pulse remote line

T

Power LED: OFF
Output LED: Flash, then OFF
Status LEDs: LO & DO alternately flashing
Bar graph: OFF

TEACH Output

OFF Condition

• Present Output OFF condition
• Click Static button

• Present Output OFF condition.
• Single-pulse remote line

T

TEACH Accepted

Power LED: ON
Bar graph: One LED flashes to show
relative contrast (good signal difference shown;
see table above)
Sensor returns to Run mode

TEACH Unacceptable

Power LED: OFF
Bar graph: #1, 3, 5, 7 alternately flash
to show failure
Sensor returns to "TEACH Output ON condition"

D10 Expert Series with Bar Graph Display and Discrete Output

P/N 117830 Rev. F

www.bannerengineering.com - tel: 763-544-3164