Operate setting (see, Setup mode, Ate setting (see – Banner D10 Series User Manual

Page 8

Advertising
background image

Setup Mode

Use Setup mode to change sensor output response for:

• Light or Dark operate
• 30-millisecond pulse stretcher (OFF-delay), if required
• 200 μs high-speed response

If Setup mode configuration is interrupted and remains inactive for 60 sec-
onds, the sensor returns to Run mode with the most recent settings (i.e.,
exits and saves current selection).
Setup mode operates in the “background,” while the outputs are active;
changes are updated instantly.

Setup status

indicators

Press and hold both

buttons for more than

2 seconds to access

Setup Mode

Push Button

0.04 seconds < "Click" < 0.8

seconds

Remote Line

0.04 seconds < T < 0.8 seconds

Result

Access Setup

Mode

• Press and hold both push but-

tons > 2 seconds

• Double-pulse remote line

T

T

T

Power LED: OFF
Output LED: remains active
Icon continue to display current setup
Static LEDs: OFF

Select Setting

Combination

• Click either push button until

LEDs show desired settings.

or

• Pulse the remote line until

LEDs show desired settings.

NOTE: Double-pulsing the remote
line will cause the setting to "back
up" one step.

Sensor toggles through eight setting combinations, in the
following order:

LO - Normal Speed - No Delay (default)
DO - Normal Speed - No Delay
LO - High Speed - No Delay
DO - High Speed - No Delay
LO - Normal Speed - Delay
DO - Normal Speed - Delay
LO - High Speed - Delay
DO - High Speed - Delay

Return to Run

Mode

• Press and hold both push but-

tons > 2 seconds

• Hold remote line low > 2 sec-

onds.

2 seconds

Power LED: ON
Sensor returns to RUN mode with new settings.

D10 Expert Series with Bar Graph Display and Discrete Output