Manual Adjust

Manual Adjust is used during Run mode and is accomplished using the push buttons only. Its behavior depends on whether a switching
threshold or a sensing window is used.
Switching Threshold:

• Fine-tunes sensing sensitivity
• Press “+” to increase; press “-” to decrease

Sensing Window:

• Adjusts sensing window size (tolerance) for the single-point target condition
• Press “+” to increase; press “-” to decrease

The lighted bar graph LEDs move to reflect the increase or decrease.

Enabling or Disabling the Push Button

In addition to its programming function, the remote line may be used to disable the push buttons for security. Disabling the push buttons
prevents undesired tampering with the sensor configuration settings.

1. Connect the sensor’s gray wire.
2. Four-pulse the remote line to enable or disable the push button.

The sensor toggles between enable and disable settings and returns to RUN mode.

Wiring Diagrams

Standard Models and Main Unit

Installing Fibers

3

1

2

4

5

10-30V dc Standard Models
12-30V dc Bussable Power Models

Remote Teach

150 mA max. load

Load

Load

+

1 - Brown
2 - White
3 - Blue
4 - Black
5 - Gray
6 - Pink (not used)

The QD hookup is functionally identi-
cal. The pink wire is not used.

Plastic fiber

emitter port

Plastic fiber

receiver port

Slides up to

release fibers

Sub-Units

NPN

PNP

5

4

Remote Teach

12-30V dc

Connection

From Main

Unit Bus

Load

+

5

4

Remote Teach

12-30V dc

Connection

From Main

Unit Bus

Load

+

D10 Expert Series with Bar Graph Display and Discrete Output

P/N 117830 Rev. F

www.bannerengineering.com - tel: 763-544-3164

9