Banner QMT72 Rope Pull Switches User Manual

Rope pull switches, Datasheet

Advertising
background image

Datasheet

•

Positive-opening safety contacts (IEC 60947-5-1), not dependent

upon springs

•

Both safety contacts latch open when rope is pulled or in case of a

broken wire; requires manual reset

•

Heavy-duty die cast metal housing, rated IP65, suitable for demanding

industrial environments

•

Rope spans up to 6 m, 12 m or 20 m (20 ft, 40 ft, or 66 ft), depending

on model

•

Both safety contacts are closed with normal rope tension; one contact

opens when rope is pulled, the other contact opens if rope breaks (or

if tension is reduced from normal amount)

•

Some models include extra contacts for monitoring or to provide dual-

channel input to a safety device

•

Indicator mark on switch shows when rope has proper tension for

operation

•

Long life, switch rated at 1 million mechanical operations, minimum

•

Five available models; all with latching outputs

•

Protective Earth Terminal (IEC 60947-1)

Model

Max. Rope

Length

Run Position

Cable Pulled

Cable Break

Switching Diagram

RP-QM72D-6L

6 m (20 ft)

25

26

13

14

25

26

13

14

25

26

13

14

13-14

25-26

Break

Pull

90N

120N

0 (0)

2 (0.08)

4 (0.16)

6 (0.24)

mm (in)

.

RP-QM72D-12L

12 m (40 ft)

25

26

13

14

25

26

13

14

25

26

13

14

13-14

25-26

Break

Pull

150N

240N

0 (0)

1.5 (0.06)

5 (0.20)

7.5 (0.30)

mm (in)

Rope Pull Switches

P/N 62084 Rev. C

27 January 2014

Advertising