M-gage, S18m, Vehicle detection sensor – Banner M-GAGE S18M Series Vehicle Detection Series User Manual

Page 4: Below-grade installation, Above-grade installation

Advertising
background image

M-GAGE

S18M —

Vehicle Detection Sensor

4

P/N 114430 rev. C

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

SMP1 Flex

Conduit Plug

¾" Flex

Conduit

2" PVC

Conduit

6" Below

Grade

Figure 2. Below-grade installation

3.

1.

2.

Below-Grade Installation

Materials

• M-GAGE S18M Sensor
• SMP1 Conduit Plug
• 2" Schedule 80 rigid PVC conduit (1.5" may be used if there

is only one 90° bend); total length and number of elbows

depend on installation layout

• 2" (or 1.5") rigid PVC end cap (1 per installation)
• ¾" I.D. flexible, liquid-tight, non-metallic conduit (same

length as PVC conduit used for application)

• DPB1 Portable Programming Box

Procedure

1) Lay out 2" (or 1.5") PVC in the desired configuration. For

the best sensor performance, the sensing location (located

at the end of the conduit run) should be 6" below the final

surface. Provide an access point where the PVC comes

above grade (where the sensor and flex conduit can be fed

in or pulled out, as required).

2) Secure the end cap to the PVC, at the sensing location.
3) Measure the overall length of the PVC run, from the

sensing location to the control panel.

4) Cut a section of ¾" flex conduit to span the total distance

from the control panel to the sensing location.

5) Thread the sensor into the SMP1 conduit plug. Feed the

sensor cable into the flex conduit, until the sensor and plug

are snugly seated in the end of the flex conduit.

6) Feed the flex conduit by hand, sensor-end first, into the

PVC access point until the sensor reaches the PVC end cap.

7) Secure the remaining flex conduit from the access point to

the control cabinet.

8) After the sensor is configured (see following section), wire

the sensor into the control device and power supply per the

wiring diagram on page 8.

Above-Grade Installation

Materials

• M-GAGE S18M Sensor
• SMP2 Conduit Plug
• ¾" Schedule 40 PVC electrical conduit; total length and

number of elbows depend on installation layout

• Electrician’s fishtape
• Silicone adhesive
• DPB1 Portable Programming Box

Procedure

1) Mount the PVC electrical conduit from the sensing point

to the control panel. Plastic conduit should be used for at

least the first 6.1 m (20') from the sensing point; metal or

flexible conduit may be used the remainder of the distance.

2) Thread the S18M sensor into the threads of the SMP2

conduit plug.

3) Feed the fishtape into the conduit, from the control panel

towards the sensing point.

4) Pull the sensor cable back through the conduit, until the

sensor almost reaches the end of the plastic conduit. Do

NOT pull sensor into conduit.

5) Apply a small amount of silicone adhesive to the outside of

the conduit at the sensing point end.

6) Press the conduit plug into the end of the conduit.
7) After the sensor is configured (see following section), wire

the sensor into the control device and power supply per the

wiring diagram on page 8.

Figure 3. Above-grade installation

SMP2 Conduit Plug

¾" PVC Conduit

2.

1.

Advertising