M-gage, S18m, Vehicle detection sensor – Banner M-GAGE S18M Series Vehicle Detection Series User Manual

Page 5: Sensor configuration, Configuration via the sensor push button

Advertising
background image

P/N 114430 rev. C

5

M-GAGE

S18M —

Vehicle Detection Sensor

Banner Engineering Corp.

Minneapolis, MN U.S.A.

www.bannerengineering.com • Tel: 763.544.3164

Sensor Configuration

For most applications, configure the M-GAGE sensor remotely, via the DPB1 Portable Programming

Box, which provides programming access to an underground or otherwise inaccessible sensor. For

optimum performance, the sensor must be fixtured so that it will not move either during or following

configuration.
Configuration using the sensor’s built-in push button is useful primarily for demonstration and

troubleshooting purposes.

Configuration via the DPB1 Portable Programming Box

PC

IR

Figure 4. Using the model DPB1 portable

programming box

“Single-Click” to Set Background

Condition

“Double-Click” to Set Sensitivity

“Four-Click” to Enable/Disable

Push Button

Brown Blue Gray White or Black

Power ON LED

Configuration/
Output ON LED

Push Button

Configuration via the Sensor Push Button

(For demonstration and troubleshooting only.)

Follow the instructions in the table above, with the following exceptions.

Set Background Condition (No Vehicle Present):

• Press and hold the push button for 2 seconds, until the Output LED turns red.

• Release, and then “click” the push button once.

Set Sensitivity Level:

• Press and hold the push button for 2 seconds, until the Output LED turns red.

• Release, and then quickly “double-click” the push button. Increase the sensitivity by increments as

described above.

• When the sensor is set to desired sensitivity level, double-click push button to return sensor to RUN

mode.

Set Background Condition (No Vehicle Present)

Wire the M-GAGE sensor to the DPB1 as shown in Figure 4. Remove all vehicles and all other metal

objects temporarily in the sensing area, before setting the background condition.

Configuration

Result

Set

Background

• “Click” the DPB1 TEACH push button once.

• Sensor learns background.

• Output indicator LED flashes

approximately 12 times, while background

is taught.

• Sensor returns to RUN mode.

Set Sensitivity Level (6 sensitivity levels; level 1 least sensitive, level 6 most sensitive)
Configuration

Result

Sensitivity

Mode

• “Double-click” the DPB1 TEACH push button.

• Output LED flashes every 2 seconds;

sensor is at sensitivity level 1.

(When using the DPB1, the sensor always

reverts to sensitivity level 1.)

Adjust

Sensitivity

• To increase the sensitivity in increments, “click” the

push button again;

continue until desired

sensitivity level is reached.

• Output LED will flash from 1 to 6 times

every 2 seconds to indicate sensor’s

sensitivity level (e.g., twice to indicate

level 2).

• “Double-click” push button

to save setting.

• Sensor returns to RUN mode

Test

Operation

• Drive a vehicle past/over sensor to trip the output;

verify Output LED comes ON as expected. Use a

small/light vehicle to ensure larger vehicles will be

detected later.

• Adjust the sensitivity as needed.

Prepare

for

Operation

• Disconnect DPB1 and hardwire sensor to

permanent power supply/output device (user-

supplied). See page 8.

Set Push Button Enable/Disable
Configuration

Result

Push

Button

Enable/Disable

• “Four-click” the DPB1 TEACH button to enable or

disable the push button.

• Sensor toggles between enable/disable

settings and returns to RUN mode