E series omni-beam™ sensors, Overview, continued – Banner OMNI-BEAM Series User Manual

Page 6

Advertising
background image

Banner Engineering Corp. • Minneapolis, MN U.S.A

www.bannerengineering.com • Tel: 763.544.3164

6

P/N 03540 rev. C

E Series OMNI-BEAM™ Sensors

OMNI-BEAM Logic Modules

E Series OMNI-BEAM sensors easily accept the addition of timing logic when needed. Three

multiple-function logic modules are available. Model OLM5 is programmable for ON-delay, OFF-

delay, or ON/OFF-delay timing logic. Models OLM8 and OLM8M1 offer either one-short or delayed

one-shot functions. Programming of the logic function, the timing range, and the output state is

done via a set of four switches located on the logic module.
Both logic modules feature 15-turn clutched potentiometers for accurate timing adjustments. The

logic module simply slides into the sensor head housing and interconnects without wires. Timing

adjustments are easily accessible at the top of the sensor head and are protected by the sensor

head’s transparent, gasketed polycarbonate

cover. Assembled sensors are rated NEMA 1, 2, 3, 3S,

4, 12, and 13.

OMNI-BEAM Logic Module Specifications

Operating Temperature: −40° to +70° C (−40° to +158° F)
Timing Adjustments: Two 15-turn clutched potentiometers with brass elements, accessible
from outside at top of sensor block, beneath gasketed cover.
Timing Repeatability: Plus or minus 2% of timing range (maximum). Assumes conditions of
constant temperature and power supply.
Useful Time Range: Useful range is from maximum time down to 10% of maximum, all
models. When timing potentiometer is set fully counterclockwise, time will be approximately
1% of maximum for models OLM5 and OLM8, and 2% of maximum for model OLM8M1.
Response Time: A disabled timing function adds no measurable sensing response time.

OLM5 Delay Timer Logic Module

Model OLM5 is programmable for ON-DELAY or OFF-
DELAY or ON/OFF DELAY timing functions. Each delay
function may be independently adjusted and separately
programmed for either a long or short adjustment range.

Timing Logic Function and Timing

Range

Switch Positions

#1

#2

#2

#4

ON-DELAY

1 second maximum

ON

OFF

OFF

OFF

ON-DELAY

15 seconds maximum

OFF

ON

OFF

OFF

OFF-DELAY

1 second maximum

OFF

OFF

ON

OFF

OFF DELAY

15 seconds maximum

OFF

OFF

OFF

ON

ON-DELAY
OFF-DELAY

1 second maximum
1 second maximum

ON

OFF

ON

OFF

ON-DELAY
OFF-DELAY

1 second maximum
15 seconds maximum

ON

OFF

OFF

ON

ON-DELAY
OFF-DELAY

15 seconds maximum
1 second maximum

OFF

ON

ON

OFF

ON-DELAY
OFF-DELAY

15 seconds maximum
15 seconds maximum

OFF

ON

OFF

ON

NOTE 1: if both ranges of either delay function are selected (i.e., if
both 1 second and 15 second switches are "on"), the delay time range
becomes 16 seconds, maximum.
NOTE 2: with switches #1 and #2 "off" (no ON-DELAY programmed),
ON-DELAY is adjustable from "negligible" up to 100 milliseconds,
maximum.
NOTE 3: with switches #3 and #4 "off" (no OFF-DELAY programmed),
OFF-DELAY is adjustable from "negligible" up to 100 milliseconds,
maximum.

The logic module slides into the sensor head

and interconnects without wires.

Slide in

Plug-in timing logic modules are available for

either delay or pulse timing functions.

Overview, continued