E Series OMNI-BEAM™ Sensors

OLM8 Pulse Timer Logic Module

Models OLM8 and OLM8M1 are programmable
for either a one-shot ("single-shot") pulse timer or
a delayed one-shot logic timer. Delay and Pulse
times may be independently adjusted and separately
configured for either a long or short adjustment range.
OLM8M1 maximum times are 1/10 those of the OLM8.

NOTE 1: DELAY is non-retriggerable.
PULSE is retriggerable if the DELAY time is less than the ONE-SHOT
pulse time.
NOTE 2: if both ranges of the delay function are selected (i.e., if both
1 second and 15 second switches are “on”), the delay time range
becomes 16 (1.6*) seconds, maximum.
NOTE 3: with switches #1 and #2 “off” (no DELAY programmed),
DELAY is adjustable from “negligible” up to 10 (4.5*) milliseconds,
maximum.

Logic Function and Timing Ranges:

models OLM8 and OLM8M1*

Switch Positions

#1

#2

#3

#4

ONE-SHOT

1 (.1) second max. pulse

OFF

OFF

OFF

-----

ONE-SHOT

15 (1.5) seconds max. pulse

OFF

OFF

ON

-----

DELAYED

1 (.1) second max. delay

ON

OFF

OFF

-----

ONE-SHOT

1 (.1) second max. pulse

DELAYED

15 (1.5) seconds max. delay

OFF

ON

OFF

-----

ONE-SHOT

1 (.1) second max. pulse

DELAYED

1 (.1) second max. delay

ON

OFF

ON

-----

ONE-SHOT

15 (1.5) seconds max. pulse

DELAYED

15 (1.5) seconds max. delay

OFF

ON

ON

-----

ONE-SHOT

15 (1.5) second max. pulse

For normally open outputs (outputs conduct during pulse time) _________ OFF