E series omni-beam™ sensors, Specifications, Configuration – Banner OMNI-BEAM Series User Manual

Page 8

Advertising
background image

Banner Engineering Corp. • Minneapolis, MN U.S.A

www.bannerengineering.com • Tel: 763.544.3164

8

P/N 03540 rev. C

E Series OMNI-BEAM™ Sensors

Specifications

Supply Voltage and Current

24 to 250V ac (50-60 Hz), or 24 to 36V dc at 45 mA dc maximum, exclusive of load.
DC hookup is without regard to polarity.

Output Configuration

One internal form “C” (single-pole double-throw) relay

Output Rating

Maximum switching power (resistive load): 150 W, 600 VA
Maximum switching voltage (resistive load): 250V ac or 30V dc
Maximum switching current (resistive load): 5 A
Minimum voltage and current: 5V dc, 0.1 A
Mechanical life of relay: 10,000,000 operations
Electrical life of relay at full resistive load: 100,000 operations

Output Response Time

20 milliseconds ON and OFF; 100-millisecond delay on power-up (relay is de-energized during this period).

Adjustments

Multi-turn Gain control on top of sensor (beneath a transparent gasketed polycarbonate cover) allows precise
sensitivity setting (turn clockwise to increase gain).
Internal switch selects LIGHT operate or DARK operate.
Optional logic module models OLM5, OLM8, and OLM8M1 have adjustable timing functions.

Indicators

Red LED indicators for Sense and Load on top of sensor (beneath a transparent gasketed polycarbonate cover).
Sense LED lights when an object is sensed. Load LED lights when the output relay is energized.

Timing Logic

Optional logic modules are available:
timing logic module OLM5 (DELAY timing logic)
timing logic module OLM8 or OLM8M1 (PULSE timing logic)

Construction

Molded thermoplastic polyester housing. Power block is totally encapsulated. Molded acrylic lenses, stainless steel
hardware. When assembled, all parts are fully gasketed.
Assembled E Series OMNI-BEAM sensors are rated NEMA 1, 2, 3, 3S, 4, 12, and 13.

Connections

Sensors may be supplied either with 2-wire (for emitter models) and 5-wire (for all other models) 6’ PVC-covered
cable and 1/2’’ NPS integral internal conduit thread in the sensor base, or integral “QD” (quick disconnect) connector.
“QD” models use 5-conductor cord sets MBCC-5.. (sold separately).

Operating Conditions

Temperature: 0° to +50° C (+32° to +122° F).
Temperature for Plastic Fiber Optics: −30° to +70° C (−20° to +158° F)

Certifications

®

E71083

LR41887-17

Configuration

Light/Dark Operate Selection

Light- or dark-operate mode selection is done via a slide switch inside
the bottom of the sensor head (see photo). To access the switch, first
remove the transparent cover from the top of the sensor head, then
unscrew the four captive assembly bolts that hold the sensor head to
the power block. The switch is easily operated with a small screwdriver.
Move the switch to the LEFT for LIGHT operate, or to the RIGHT for
DARK operate (switch position information is inscribed on the printed
circuit board, next to the switch).
In LIGHT operate, the output is energized when the sensor “sees” light.
In DARK operate, the output is energized when the sensor “sees” dark.

LIGHT/DARK switch

LO

DO

Advertising