Banner RP-RM83F Rope Pull Switches User Manual

Datasheet

Advertising
background image

Datasheet

Rope pull switch with an emergency stop button for indoor or outdoor use

•

Both safety contacts latch open when rope is pulled, broken, or if

tension is reduced; requires manual reset (IEC 60947-5-5)

•

Aluminum die-cast housing, rated IP67 and NEMA 4, suitable for

demanding indoor and outdoor industrial environments

•

Innovative RP-RM83F-..LT.. design provides quick, easy rope

adjustment

•

Rope spans up to 75 m (245 ft), depending on model

•

Both safety contacts are closed with normal rope tension, and open

when rope is pulled or if rope breaks (or if tension is reduced from

normal amount)

•

Both Monitoring contacts operate opposite the safety contacts for

monitoring by another device

•

Additional Aux. 24V solid-state PNP output on some models provides

remote rope tension monitoring

•

Tension indicator window indicates proper rope tension for operation or

safety contacts latched open (the rope pull or the E-stop button is

actuated)

Model

Max. Rope

Length

Rope Connection

Aux.

Status

Output

Run Position

Cable

Pulled/

Cable Break

Switching Diagram

RP-RM83F-75LTE

75 m (245 ft)

Built-in Turnbuckle

Yes

Cable Run Position (All

Models)

No PNP Aux. Output

Models

RP-RM83F-75LRE

Ring

S1

S2

-6

+6

-4.8
-4

+4

mm

+4.8

11-12

23-24

Break (91N/156N)

11-12

23-24

S2

S1

Tension

Set Point

133N/228N

Latch

Pull (175N/300N)

Latch

Safety

Monitor

Safety

Monitor

RP-RM83F-75LT

Built-in Turnbuckle

No

12

11

24

23

12

11

24

23

RP-RM83F-75LR

Ring

RP-RM83F-38LTE

37.5 m (123

ft)

Built-in Turnbuckle

Yes

Cable Pulled / Cable Break

Position (All Models)

PNP Aux. Output Models

RP-RM83F-38LRE

Ring

S1

S2

-6

+6

-4.8
-4

-3

+4

+3

mm

+4.8

11-12

23-24

Break (91N/156N)

11-12

23-24

2-3

S2

S1

Tension

Set Point

133N/228N

Latch

Pull (175N/300N)

Latch

Safety

Monitor

Safety

Monitor

Aux.

Aux.

RP-RM83F-38LT

Built-in Turnbuckle

No

12

11

24

23

12

11

24

23

RP-RM83F-38LR

Ring

Contacts:

Open

Closed

NOTE: This symbol

for a positive-opening safety contact (IEC 60947-5-1) is used in the switching

diagram to identify the point in actuator travel where the normally-closed safety contact is fully open.

RP-RM83F Heavy-Duty Rope Pull

Emergency Stop Switches

P/N 141245 Rev. C

7 February 2014

141245

Advertising