Pak 200i – Tweco PAK 200i User Manual

Page 144

Advertising
background image

PAK 200i

A-64

APPENDIX

Manual 0-5335

Possible causes:

• Cooling fan(s) not operating.
• Disrupted air flow.
• Defective inverter module.
• Inverter Ribbon cable bad connection.
• Defective CCM.

Originally 100 and 200A units had 2 smaller fans while 300 & 400A used a single larger fan along with a larger

radiator. More recently, the single larger fan may be used in the 100 & �00A as well.

Troubleshooting:

1. Confirm that air is exhausting from both the top (top fan)and bottom (bottom fan of units with 2 fans) of the

opening in the right side panel. As the fan(s) are behind the radiator it’s hard to see them to confirm they

are turning but perhaps you can use an inspection mirror. Refer to section for code 403 for troubleshooting

defective fans.

!

WARNING!

Fan blades can be moving and accidental contact with a mirror or other inspection devise can cause personal injury

or damage to the machine.

2. Leaving the side panels and cover off, especially the left lower side or the top cover will reduce the air flow.

Also if the radiator fins become clogged with dust it will reduce air flow. Clean the radiator periodically by

blowing air into it to clear dirt from the fins.

259-264 Inverter Over Temperature due to high Ambient.

The CCM measures the ambient temperature where the cooling air enters the louvers on the left side of the

front panel. If an inverter goes over temperature and we have determined that the ambient exceeds 40 deg C

we will get one or more of the high ambient codes, 252-264. The sensor, TS2, is a NTC (Negative Temperature

Coefficient) resistor whose resistance varies with temperature. It is mounted on the inside of the front panel

next to the louvers on the left. To access it requires removing one or more of the inverter modules. If the ambi-

ent is high but no inverter is too hot there is no fault.

Possible causes:

• Ambient is too high.
• Cooling fan(s) not operating.
• Disrupted air flow.
• TS2, Ambient temperature sensor, shorted (very unlikely) or otherwise defective.
• Defective Relay board.
• Defective CCM.
• Defective Relay board.

Troubleshooting:

1. If room temperature exceeds 40 deg C, cool the room, or operate the unit at reduced duty cycle or lower

current.

2. Confirm that air is exhausting from opening in the right side panel. As the fan(s) are behind the radiator

it’s hard to see them to confirm they are turning but perhaps you can use an inspection mirror. Be careful

not to get the mirror or your hands into the blades. 100 & 200A units have 2 smaller fans, 300 & 400A have

one larger one.

3. It is unlikely these high ambient temperature codes would be set before some other temperature related code

but just in case we’ll note that leaving the side panels and cover off, especially the left lower side or the top

cover will reduce the air flow. Also the radiator fins clogged with dust will reduce air.