05 primary power connections, Primary power connections -4, Pak 200i – Tweco PAK 200i User Manual

Page 28

Advertising
background image

PAK 200i

3-�

INSTALLATION

Manual 0-5335

3.05 Primary Power Connections

The primary power cable and through hole cable grip must be supplied by the end user and connected to the power

supply. Refer to local and national electrical codes for suggested cable and fuse sizes.

Remove the left side covers of the Power Supply.

Connect Input Power and System Ground Cables for 480V and 380V systems (Non CE)

1. Carefully cut back the outer sheath on the primary input power cable to expose the individual wires. Cut back

the insulation on the individual wires. Route the cable through the rear panel of the power supply.

�. Insert the individual wires into the proper terminals on the contactor as shown. There are factory installed wires

already attached to these same terminals and will need to be loosened first. Do Not remove these wires. Tighten

the screws onto both sets of wires using a 4mm hex key wrench.

Art # A-11550_AB

4mm

3. Connect the input power cable ground wire to the ground terminal block as shown above.

4. Connect a system ground cable (F1) to the ground terminal on the outside of the power supply located next to

the Torch Leads port. Refer to the Ground Connections Section for full details and procedures on proper system

grounding.

5. Two extra plates are included at the cable entrance. Discard one or both to allow change of the opening size for

larger cable/strain relief.

Advertising