4.03 Operating Set-up

Follow this set-up procedure each time the system is operated:

WARNING

Disconnect primary power at the source before assembling or disassembling power supply, torch parts, torch and

leads assemblies or adding coolant.

A. Coolant Level Inspection

Check the coolant level in the coolant tank at the front of the unit. If the tank is below 3/4 full, add coolant.

B. Torch Parts Selection

Check the torch for proper assembly. Install proper torch parts for the application per the Torch section of the

manual..

C. Input Power

Check the power source for proper input voltage. Close main disconnect switch or plug unit in to supply pri-

mary power to the system.

D. Work Cable Connection

Check for a solid and clean work cable connection to the workpiece or cutting table. The connection area must

be free from paint and rust.

E. Torch Connection

Check that the torch is properly connected.

F. Gas Supplies

Connect desired plasma and shield gases. Make sure gas sources meet requirements. Check connections and

turn gas supply on. Set Gas Selection Switch on rear panel to the correct plasma gas being used.

G. Plasma Gas Purge

Move the Power Supply ON/OFF switch to the ON position.

An automatic gas purge will remove any condensation that may have accumulated in the torch and leads while

the system was shut down. After the purge is complete, if the RUN/SET switch is in SET position, gases will flow.

H. Amperage Selection

Select the desired current output amperage.

I. Pressure Settings

1. Refer to the cut charts in section 4.08 for pressure details according to the material being cut. Move the RUN/

SET switch to SET position. (Gas will flow through the torch). Set gas pressures and flows as follows:

�. To set the Plasma Gas pressure:

a. Pull out the knob on the Plasma Gas pressure control knob.

c. Turn the knob to adjust gas pressure.

d. Push the knob back in to lock the pressure setting.