11 fill cooling system, Fill cooling system -12, Pak 200i – Tweco PAK 200i User Manual

Page 36

Advertising
background image

PAK 200i

3-1�

INSTALLATION

Manual 0-5335

3:11 Fill Cooling System

Cooling System Requirements

Coolant must be added to the system on installation. The amount required varies with torch leads length.

Victor Thermal Dynamics recommends the use of its coolants 7-35�0 and 7-35�1 (for low temperatures).

Coolant Capabilities

Cat. Number and Mixture

Mixture

Protects To

7-3580 ‘Extra-Cool

TM

25 / 75

10° F / -12° C

7-3581 ‘Ultra-Cool

TM

50 / 50

27° F / -33° C

7-3582 ‘Extreme Cool

TM

Concentrate*

-65° F / -51° C

* For mixing with D-I Cool

TM

7-3583

1. Fill the coolant tank to the level shown, with Victor Thermal Dynamics coolant. The coolant level is visible

through the translucent coolant tank. The amount of coolant required varies with torch leads length.

2. Replace the cap on the tank.

Art # A-11463

Fill Range

Coolant Tank

3. After the complete system has been installed, check that the coolant has been pumped through the system

as follows (see NOTE):

NOTE

The system will most likely require more coolant after turning the system ON for the first time.

a. Place the ON/OFF Switch to ON. The power supply will start to circulate coolant throughout the system.

b. After about � minutes the system may shut down if the leads are not full of coolant.

c. Place the ON/OFF switch to OFF. Refill Coolant Tank as needed.

Advertising