Tweco SL100 User Manual

Page 14

Advertising
background image

INTRODUCTION

2-2

Manual 0-2962

E. Type Cooling

Combination of ambient air and gas stream through

torch.

F. Torch Ratings

Ambient

Temperature

104° F

40° C

Duty Cycle

100% @ 60 Amps @ 400 scfh

Maximum Current

60 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

7kV

SL60 Torch Ratings

Ambient

Temperature

104° F

40° C

Duty Cycle

100% @ 100 Amps @ 400 scfh

Maximum Current

100 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

7kV

SL100 Torch Ratings

G. Current Ratings

SL60 Torch & Leads Up to 60 Amps, DC,

Straight Polarity

SL100 Torch & Leads Up to 100 Amps, DC,

Straight Polarity

Current Ratings

!

WARNING

Maximum current is 60 Amps for SL60 Torches,

or 100 Amps for SL100 Torches. Operation of

this torch at higher outputs may damage the

torch, the leads, the components, or the Power

Supply. DO NOT operate the SL60 torch at

more than 60 Amps, or the SL100 at more

than 100 Amps.

NOTE

Power Supply characteristics will determine

material thickness range.

H. Gas Requirements

Gas (Plasma and Secondary)

Compressed Air

Operating Pressure

Refer to NOTE

60 - 75 psi

4.1 - 5.2 bar

Maximum Input Pressure

125 psi / 8.6

bar

Gas Flow (Cutting and Gouging)

300 - 500 scfh

142 - 235 lpm

SL60 and SL100 Torch Gas Specifications

!

WARNING

This torch is not to be used with oxygen (O

2

).

NOTE

Operating pressure varies with torch model,

operating amperage, and torch leads length.

Refer to gas pressure settings charts for each

model.

I. Direct Contact Hazard

For exposed tip the recommended standoff is 3/16

inches / 4.7 mm.

J. Plasma Power Supply Used With

• CutMaster 50
• CutMaster 51
• CutMaster 75
• CutMaster 81
• CutMaster 100
• CutMaster 101
• CutMaster 151
• PakMaster 50XL Plus
• PakMaster 75XL Plus
• PakMaster 100XL Plus

NOTE

Refer to the Appendix Pages for additional

specifications as related to the Power Supply

used.

Advertising