INSTALLATION

3. Secure the Through - Hole protector with the retain-

ing nut removed earlier.

4. Connect the torch leads or ATC Adapter Negative

/ Plasma Lead to the bulkhead connection inside

the Power Supply as shown.

Adapter

Plug

Pilot Lead

Torch Leads
Assembly or

ATC Adapter

Negative/Plasma

Lead

Adapter

Connector

Pilot Lead Stud

Negative/Plasma Lead

Connection

A-03527

Control Circuit

Connectors

Note: Actual Bulkhead
configuration may
differ from that shown.

Bulkhead Connections - ATC Adapter or Hand Torch

Leads with O2B Fittings

5. The Leads or ATC Adapter Assembly includes two

wires joined with mating connectors and covered

with an insulating sleeve. These wires must remain

joined and insulated. Connect the remaining torch

leads connectors to the mating connectors on the

Power Supply Adapter.

6. Remove the top nut and washer from the Pilot Stud.
7. Connect the pilot lead terminal to the stud and

secure with the nut and washer removed in the

above Step.

8. Tighten the Through - Hole protector onto the Torch

Leads or ATC Adapter Leads Assembly.

9. For torches with the ATC Connector, align the

torch leads male connector with the ATC female

receptacle. Push the male connector into the

female receptacle. The connectors should push

together with a very small amount of pressure.

Secure the connection by turning the locking nut

clockwise until it stops. DO NOT use the locking

nut to pull the connection together. Do not use

tools to secure the connection.

A-03627

1

2

ATC Male
Connector

ATC Adapter
Female Receptacle

Torch Leads

To

Power Supply

Torch Connection - Torch Leads with ATC Male

Connector, Power Supply with ATC Adapter

1

2

Control Cable
Connector (Machine
Torches Only)

ATC Male
Connector

ATC Female Receptacle
(Panel Mounted)

A-03602

Torch Connection - Torch Leads with ATC Male

Connector, Power Supply with Panel-Mounted ATC

Receptacle

10. Check the torch for proper consumable parts.

CAUTION

The torch parts must correspond with the type

of operation. Refer to Section 4.04, Torch Parts

Selection.