Latch – Tweco SL100 User Manual

Page 57

Advertising
background image

Manual 0-2962

A-1

APPENDIX

APPENDIX 1: TYPICAL SYSTEM SEQUENCE OF OPERATION BLOCK

DIAGRAM

ACTION

ON/OFF-Switch to OFF.

RESULT

All indicators OFF.

Power supply fan(s) off.

ACTION

Mode Switch* to RUN.

RESULT

Gas flow stops.

GAS indicator off.

ACTION

Torch moved within

transfer distance of workpiece.

RESULT

Main arc transfers.

Pilot arc off.

ACTION

Torch deactivated (by torch switch

release or by remote device).

RESULT

Main Arc stops.

(Power supply enable signal removed.)

Gas flows briefly.

NOTE - If torch is activated during

post-flow, pilot arc will immediately restart.

If torch is within transfer distance (3/8 in) of

workpiece, main arc will transfer.

After post-flow:

Gas solenoid closes, gas flow stops.

GAS indicator off.

ACTION

Open external

disconnect switch.

RESULT

No power to system.

ACTION

Close external

disconnect switch.

RESULT

Power to system.

ACTION

Mode Switch* to SET.

RESULT

Gas Solenoid open, gas

flows to set pressure.

GAS indicator ON.

ACTION

Torch moved away

from work (while still

activated)

RESULT

Main arc stops.

Pilot arc automatically

restarts.

PILOT ARC

ACTION

ON/OFF-Switch to ON.

RESULT

AC indicator blinks for 8

seconds, then steady on.

Fans on.

Power circuit ready.

ACTION

Protect eyes and

activate torch.

RESULT

Gas flows

(2 seconds)

After gas pre-flow:

DC indicator ON.

Pilot relay closes.

Pilot arc established.

Art # A-03779

LATCH

* Mode switch settings in PakMaster Series are RUN / SET / LATCH.
* Mode switch settings in CutMaster 50, CutMaster 75 and CutMaster 100 are RUN / SET.
* Mode switch settings in CutMaster 51, CutMaster 81 and CutMaster 101 are RUN /
RAPID AUTO RESTART / SET.

Torch switch

can be released.

RESULT

Transfer will continue

until torch is removed

from workpiece.