Appendix 11: mechanized torch wiring diagrams, Unshielded sl100 mechanized (machine) torch, Torch & unshielded leads with o2b connector – Tweco SL100 User Manual

Page 83

Advertising
background image

Manual 0-2962

A-27 APPENDIX

APPENDIX 11: MECHANIZED TORCH WIRING DIAGRAMS

Not Used

PIP

Switch

Unshielded SL100 Mechanized (Machine) Torch

Art # A-03680

Orange

Black

Green

White

Torch Head

Not Used

Not Used

PIP

Switch

1

2

3

4

1

2

3

4

ATC

Male

Connector

ATC Adapter

Female

Receptacle

Pilot

Orange

Black

White

8

5

7

Torch Leads

Torch Head

Negative / Plasma

Remote

Pendant

Connector

Not Used

Remote

Pendant

Adapter

Green

Black

Pilot

Negative / Plasma

Power Supply

Bulkhead

Pilot

Power Supply

Bulkhead

Negative / Plasma

Green

White

Not Used

Not Used

PIP

Switch

1

2

3

4

1

2

3

4

ATC Male

Connector

Pilot

White

8

5

7

Torch Leads

Torch Head

Negative / Plasma

Green

Black

Pilot

ATC Female

Receptacle

Negative / Plasma

Torch & Unshielded Leads

with O2B Connector

Mechanized Torch &

Unshielded Leads

with ATC Connector

Torch & Unshielded Leads

with ATC Connector, Power Supply

with Unshielded ATC Adapter

ATC Adapter

Assembly

Torch & Unshielded Leads

with ATC Connector, Power Supply

with Console-Mounted ATC Receptacle

O2B Leads

Connector

Power Supply

Adapter

Power Supply

Adapter

Pilot

Torch Leads

Negative / Plasma

Torch & Unshielded Leads
with O2B Leads Connector

Remote

Pendant

Connector

Power Supply

Front Panel

Black

Orange

To Power Supply

Internal Connections

Mechanized Torch &

Unshielded Leads

with ATC Connector

Advertising
This manual is related to the following products: