INSTALLATION

E. Automated Machine Torch Systems with ATC

Connectors

Torches with shielded leads and ATC connectors connect

to a shielded ATC Adapter which connects to the power

supply bulkhead.

WARNING

Disconnect primary power at the source before

disassembling the torch or torch leads.

Strain Relief

Nut

Strain Relief

Shielded ATC Adapter

Pilot Lead

Negative/Plasma

Lead

Torch Control

Connectors

Shield

Connector

Shield

Connector

A-03677

Through - Hole protector Nut Removal

1. Remove the Through - Hole protector Nut from

the Through - Hole protector. Inside the Power

Supply Bulkhead area, route the connectors on the

free end of the Adapter through the Through - Hole

protector Nut.

2. Fit the ATC Adapter end and the Through - Hole

protector into the hole in the unit.

3. Secure the Through - Hole protector with the retain-

ing nut removed earlier.

4. Connect the ATC Adapter Negative / Plasma Lead to

the bulkhead connection inside the Power Supply.

5. Remove the top nut and washer from the Pilot Stud.
6. Connect the pilot lead terminal to the stud and se-

cure with the nut and washer removed previously.

7. Connect the ATC Adapter connectors to the power

supply adapter.

WARNING

The Shielded ATC Adapter includes two connec-

tors that are not used and must be taped out

of the way to prevent contacting the Negative

/ Plasma or Pilot Leads.

8. Tighten the Through - Hole protector onto the ATC

Adapter leads.

9. Connect the torch leads male connector to the ATC

female receptacle. The connectors should push

together with a very small amount of pressure.

Secure the connection by turning the locking nut

clockwise until it stops. DO NOT use the locking

nut to pull the connection together. Do not use

tools to secure the connections.

A-03627

1

2

ATC Male
Connector

ATC Adapter
Female Receptacle

Torch Leads

To

Power Supply

Torch Connection - Torch Leads with ATC Male

Connector, Power Supply with ATC Adapter

10. Check the torch for proper consumable parts.

CAUTION

The torch parts must correspond with the type

of operation. Refer to Section 4.04, Torch Parts

Selection.