2.05 Input Wiring Specifications

CutMaster 102 Power Supply Input Cable Wiring Requirements

Input

voltage

Freq Power

Input

Suggested Sizes

Volts

Hz

kVA

I max I1eff

Fuse

(amps)

Flexible Cord

(Min. AWG)

1

Phase

208

50/60

20.6

99

76

100

4 Type W

230

50/60

21.9

95

74

100

4 Type W

460

50/60

27.6

60

46

60

6

3

Phase

208

50/60

17.7

49

38

60

6

230

50/60

17.9

45

36

60

6

380

50/60

18.4

28

22

32

10

400

50/60

18.7

27

22

32

10

460

50/60

23.1

29

22

30

10

600

50/60

22.8

22

17

25

12

Line Voltages with Suggested Circuit Protection and Wire Sizes

Based on National Electric Code and Canadian Electric Code

NOTE

Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations

refer to local or national codes.