2.05 Input Wiring Specifications
CutMaster 102 Power Supply Input Cable Wiring Requirements
Input
voltage
Freq Power
Input
Suggested Sizes
Volts
Hz
kVA
I max I1eff
Fuse
(amps)
Flexible Cord
(Min. AWG)
1
Phase
208
50/60
20.6
99
76
100
4 Type W
230
50/60
21.9
95
74
100
4 Type W
460
50/60
27.6
60
46
60
6
3
Phase
208
50/60
17.7
49
38
60
6
230
50/60
17.9
45
36
60
6
380
50/60
18.4
28
22
32
10
400
50/60
18.7
27
22
32
10
460
50/60
23.1
29
22
30
10
600
50/60
22.8
22
17
25
12
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
I1max is taken at TDC rated minimum duty cycle.
I1eff is taken at TDC 100% rated duty cycle.