05 gas connections, Gas connections -4, Cutmaster 102 – Tweco 102 Cutmaster User Manual

Page 26

Advertising
background image

CUTMASTER 102

INSTALLATION

Manual 0-4997

3-4

3.05 Gas Connections

Connecting Gas Supply to Unit

The connection is the same for compressed air or high pressure cylinders. Refer to the following two subsections if an op-

tional air line filter is to be installed.

1. Connect the air line to the inlet port. The illustration shows typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do not use

Teflon tape as a thread sealer, as small particles of the tape may break off and block the small air passages in the

torch.

Art # A-07943

Hose Clamp

Regulator/Filter

Assembly

Inlet Port

Gas Supply

Hose

1/4 NPT or ISO-R

to 1/4” (6mm) Fitting

Air Connection to Inlet Port

Installing Optional Single - Stage Air Filter

An optional filter kit is recommended for improved filtering with compressed air, to keep moisture and debris out of the torch.

1. Attach the Single - Stage Filter Hose to the Inlet Port.

2. Attach the Filter Assembly to the filter hose.

3. Connect the air line to the Filter. The illustration shows typical fittings as an example.

NOTE

For a secure seal, apply thread sealant to the fitting threads, according to the maker's instructions. Do Not use

Teflon tape as a thread sealer, as small particles of the tape may break off and block the small air passages in the

torch. Connect as follows:

Advertising