Cutmaster 102 – Tweco 102 Cutmaster User Manual

Page 39

Advertising
background image

CUTMASTER 102

Manual 0-4997

OPERATION

4T-5

3. Keep the torch in contact with the workpiece during

the cutting cycle.

4. Hold the torch away from your body.

5. Slide the trigger release toward the back of the torch

handle while simultaneously squeezing the trigger.

The pilot arc will start.

A-02986

Trigger

Trigger Release

6. Bring the torch within transfer distance to the work.

The main arc will transfer to the work, and the pilot

arc will shut OFF.

NOTE

The gas preflow and postflow are a characteristic

of the power supply and not a function of the torch.

3

4

Art # A-03383

Trigger

2

1

Trigger Release

7. Cut as usual. Simply release the trigger assembly to

stop cutting.

8. Follow normal recommended cutting practices as

provided in the power supply operator's manual.

NOTE

When the shield cup is properly installed, there

is a slight gap between the shield cup and the

torch handle. Gas vents through this gap as part

of normal operation. Do not attempt to force the

shield cup to close this gap. Forcing the shield cup

against the torch head or torch handle can damage

components.

Piercing With Hand Torch

1. The torch can be comfortably held in one hand or

steadied with two hands. Position the hand to press

the Trigger on the torch handle. With the hand torch,

the hand may be positioned close to the torch head

for maximum control or near the back end for maxi-

mum heat protection. Choose the technique that

feels most comfortable and allows good control and

movement.

NOTE

The tip should never come in contact with the

workpiece except during drag cutting operations.

2. Angle the torch slightly to direct blowback particles

away from the torch tip (and operator) rather than

directly back into it until the pierce is complete.

3. In a portion of the unwanted metal start the pierce

off the cutting line and then continue the cut onto the

line. Hold the torch perpendicular to the workpiece

after the pierce is complete.

4. Hold the torch away from your body.

5. Slide the trigger release toward the back of the torch

handle while simultaneously squeezing the trigger.

The pilot arc will start.

A-02986

Trigger

Trigger Release

6. Bring the torch within transfer distance to the work.

The main arc will transfer to the work, and the pilot

arc will shut OFF.

NOTE

The gas preflow and postflow are a characteristic

of the power supply and not a function of the torch.
When the shield cup is properly installed, there

is a slight gap between the shield cup and the

torch handle. Gas vents through this gap as part

of normal operation. Do not attempt to force the

shield cup to close this gap. Forcing the shield cup

against the torch head or torch handle can damage

components.

Advertising