Optional Two-Stage Filter Element Replacement

The Two-Stage Air Filter has two Filter Elements. When the

Filter Elements become dirty the Power Supply will continue

to operate but cut quality may become unacceptable. Refer

to Section 6, Parts List, for replacement filter element catalog

number.

1. Shut OFF primary input power.

2. Shut OFF air supply and bleed down system.

WARNING

Always turn OFF the air supply and bleed the system

before disassembling the Filter Assembly as injury

could result.

3. Loosen the two bolts on the top of the Filter As-

sembly enough to allow the Filter Elements to move

freely.

4. Note the location and orientation of the old Filter Ele-

ments.

5. Slide out the old Filter Elements.

First & Second

Stage

Cartridges

(as marked)

Art # A-02942

Optional Two-Stage Filter Replacement

6. Slide the replacement Filter Elements into the Filter

Assembly, with the same orientation as noted in Step

4 above.

7. Hand tighten the two bolts evenly, then torque each

bolt to 20 - 30 in-lbs (2.3 - 3.4 Nm). Improper

torque may damage the gasket.

8. Slowly apply air pressure to the assembly, checking

for leaks.

NOTE

A small amount of air leakage from the bottom

fitting is normal.

This completes the parts replacement procedures.