4t.05 gouging, 4t.05 gouging t-6, Cutmaster 102 – Tweco 102 Cutmaster User Manual

Page 40

Advertising
background image

CUTMASTER 102

OPERATION

Manual 0-4997

4T-6

7. Clean spatter and scale from the shield cup and the

tip as soon as possible. Spraying the shield cup in

anti - spatter compound will minimize the amount of

scale which adheres to it.

Cutting speed depends on material, thickness, and the opera-

tor’s ability to accurately follow the desired cut line. The fol-

lowing factors may have an impact on system performance:

• Torch parts wear

• Air quality

• Line voltage fluctuations

• Torch standoff height

• Proper work cable connection

4T.05 Gouging

!

WARNING

Be sure the operator is equipped with proper

gloves, clothing, eye and ear protection and that all

safety precautions at the front of this manual have

been followed. Make sure no part of the operator’s

body comes in contact with the workpiece when

the torch is activated.

Disconnect primary power to the system before

disassembling the torch, leads, or power supply.

CAUTION

Sparks from plasma gouging can cause damage

to coated, painted or other surfaces such as glass,

plastic, and metal.
Check torch parts. The torch parts must correspond

with the type of operation. Refer to Section 4T.07,

Torch Parts Selection.

Gouging Parameters

Gouging performance depends on parameters such as

torch travel speed, current level, lead angle (the angle be-

tween the torch and workpiece), and the distance between

the torch tip and workpiece (standoff).

CAUTION

Touching the torch tip or shield cup to the work

surface will cause excessive parts wear.

Torch Travel Speed

NOTE

Refer to Appendix Pages for additional information

as related to the Power Supply used.

Optimum torch travel speed is dependent on current set-

ting, lead angle, and mode of operation (hand or machine

torch).

Current Setting

Current settings depend on torch travel speed, mode of

operation (hand or machine torch), and the amount of

material to be removed.

Pressure Setting

Even though the setting is within the specified range, if

the torch does not pilot well the pressure may need to be

reduced.

Lead Angle

The angle between the torch and workpiece depends on

the output current setting and torch travel speed. The

recommended lead angle is 35°. At a lead angle greater

than 45° the molten metal will not be blown out of the

gouge and may be blown back onto the torch. If the lead

angle is too small (less than 35°), less material may be

removed, requiring more passes. In some applications,

such as removing welds or working with light metal, this

may be desirable.

35°

Workpiece

Torch Head

Standoff Height

A-00941_AB

Gouging Angle and Standoff Distance

Advertising