Section 3 torch: installation, 3t.01 torch connections, 3t.02 setting up mechanical torch – Tweco 102 Cutmaster User Manual

Page 29: Section 3 torch, Installation t-1, Cutmaster 102

Advertising
background image

CUTMASTER 102

Manual 0-4997

INSTALLATION

3T-1

SECTION 3 TORCH:

INSTALLATION

3T.01 Torch Connections

If necessary, connect the torch to the Power Supply. Connect

only the Thermal Dynamics model SL100 / Manual or SL100

/ Mechanical Torch to this power supply. Maximum torch

leads length is 100 feet / 30.5 m, including extensions.

WARNING

Disconnect primary power at the source before

connecting the torch.

1. Align the ATC male connector (on the torch lead)

with the female receptacle. Push the male connector

into the female receptacle. The connectors should

push together with a small amount of pressure.

2. Secure the connection by turning the locking nut

clockwise until it clicks. DO NOT use the locking nut

to pull the connection together. Do not use tools to

secure the connection.

1

2

Art # A-07885

Connecting the Torch to the Power Supply

3. The system is ready for operation.

Check Air Quality

To test the quality of air:

1. Put the ON / OFF

switch in the ON (up)

position.

2. Put the Function Control switch in the SET

position.

3. Place a welding filter lens in front of the torch and

turn ON the air. Do not start an arc!

Any oil or moisture in the air will be visible on the lens.

3T.02 Setting Up Mechanical Torch

NOTE

An adapter is required to be installed in the power

supply if converting a hand torch system to operate

a machine torch.

WARNING

Disconnect primary power at the source before

disassembling the torch or torch leads.

The mechanical torch includes a positioning tube with rack

and pinch block assembly.

1. Mount the torch assembly on the cutting table.

2. To obtain a clean vertical cut, use a square to align

the torch perpendicular to the surface of the work-

piece.

Advertising